[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-463995-105":59,"doc-detail-463995-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","active-compensation-fault-tolerant-control-for-uncertain-systems-with-both-actuator-and-sensor-faults","Active Compensation Fault-Tolerant Control for Uncertain Systems with Both Actuator and Sensor Faults","","This paper develops a novel fault reconstruction method and an FR-based fault-tolerant control scheme for systems affected simultaneously by sensor and actuator faults. A Luenberger-like reduced-order observer combined with an interval observer is used to decouple sensor fault components and unknown inputs. The design enables asymptotic convergence of state and sensor-fault estimates, and proposes algebraic multiple-unknown-input reconstruction for accurate active reconstruction. The resulting closed-loop system remains asymptotically stable and satisfies the separation principle, supported by simulation examples.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/active-compensation-fault-tolerant-control-for-uncertain-systems-with-both-actuator-and-sensor-faults/463995/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/active-compensation-fault-tolerant-control-for-uncertain-systems-with-both-actuator-and-sensor-faults/463995.png","ImageObject",300,407,{"name":92,"@type":93},"anakgang17","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-09","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",17,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What core method is proposed for fault reconstruction in this work?","Question",{"text":113,"@type":114},"The paper develops a novel fault reconstruction approach based on combining a Luenberger-like reduced-order observer with an interval observer to handle both sensor and actuator faults.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the scheme deal with both sensor and actuator faults simultaneously?",{"text":118,"@type":114},"It introduces an output transformation to decouple the sensor fault, and forms a multiple unknown input to address external disturbance and actuator fault, then designs observers to reconstruct these components.",{"name":120,"@type":111,"acceptedAnswer":121},"What guarantees stability and theoretical properties of the fault-tolerant control scheme?",{"text":122,"@type":114},"The closed-loop system is shown to be asymptotically stable under simultaneous sensor and actuator faults, and the observer-based FTC mechanism satisfies the separation principle.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},463995,1790817620,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":46,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":31,"preview_page_count":19,"preview_urls":145},962090883568,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Article  \nActive Compensation Fault-Tolerant Control for Uncertain Systems with Both Actuator and Sensor Faults  \nXufeng Ling 1, Haichuan Xu 2 and Fanglai Zhu 2,3, *  \nAcademic Editors: Yuan Yao and Jia-Lin Kang  \nReceived: 4 December 2025  \nRevised: 24 December 2025  \nAccepted: 30 December 2025  \nPublished: 1 January 2026  \nCopyright: © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 School of Artificial Intelligence, Shanghai Normal University Tianhua College, Shanghai 201815, China; [lxf1131@sthu.edu.cn](lxf1131@sthu.edu.cn)  \n2 Shanghai Research Institute for Intelligent Autonomous Systems, Tongji University, Shanghai 200092, China; [xuhaichuan@tongji.edu.cn](xuhaichuan@tongji.edu.cn)  \n3 School of Electronics and Information Engineering, Tongji University, Shanghai 201804, China  \n* Correspondence: [zhufanglai@tongji.edu.cn](zhufanglai@tongji.edu.cn)  \nAbstract  \nThis paper develops a novel fault reconstruction (FR) method and an FR-based faulttolerant control (FTC) scheme for systems suffering from both sensor and actuator faults based on the combination of a Luenberger-like reduced-order observer and an interval observer. Firstly, by introducing an output transformation, an auxiliary output that is able to decouple the sensor fault is obtained. Secondly, for addressing the external disturbance and actuator fault, a multiple unknown input (MUI) is formed, and a reduced-order observer that is able to decouple the MUI is constructed. Consequently, asymptotic convergence estimations of the state and the sensor fault can be accomplished. Thirdly, in order to obtain the asymptotic convergence actual FR (AFR), an interval observer is designed. After this, an algebraic connection of the MUI and the state error estimation is given, and, based on the algebraic relationship, an algebraic MUI reconstruction (MUIR) method is proposed. Finally, an FTC scheme is developed by using the state estimation and MUIR. Under the FTC, the closed-loop system is asymptotically stable even if it suffers from sensor and actuator faults simultaneously. Theoretical analysis demonstrates that the observer-based FTC mechanism satisfies the separation principle. At last, two simulation examples are given to verify the effectiveness of the proposed methods.  \nKeywords: actuator and sensor faults; fault reconstruction; reduced-order observer; interval observer; multiple unknown input  \n1. Introduction  \nEnsuring the reliability and safety of practical control system operations is always a critical and challenging issue in control theory and control engineering. Actuators and sensors, as essential components, are particularly vulnerable to malfunctions due to their frequent operations in harsh environments [1–6], resulting in faults which may greatly degrade system performances. Therefore, the techniques of fault detection (FD), fault reconstruction (FR), and fault-tolerant control (FTC) play crucial roles in maintaining system performances when systems suffer from actuator and sensor faults. Hence, the FD, FR, and FTC techniques have been investigated intensively for decades and many significant methods have been developed for varieties of control systems [7–19] . For instance, in [11], a distributed adaptive event-triggered FTC scheme was proposed with a hierarchical structure for heterogeneous multi-agent systems (MASs), which prevents fault propagation and eliminates the need for continuous communication between agents. In [12], FDI of  \nan active suspension system with actuator and sensor faults was investigated with two unknown input observers. FR can let the designers know more information about systems and, thus, make the designs much more convenient. Many researchers have explored FR techniques in the context of various control systems [13–16] . In [17], an intelligent-observerbased precise and fast AF","cbCaieUorn4c28MX","https://ap.wps.com/l/cbCaieUorn4c28MX","pdf",535745,"English","# Introduction\n## Fault Detection, Fault Reconstruction, and Fault-Tolerant Control\n## Active vs Passive Fault-Tolerant Control\n## Related Work on Observer-Based Fault-Tolerant Control","[{\"question\":\"What core method is proposed for fault reconstruction in this work?\",\"answer\":\"The paper develops a novel fault reconstruction approach based on combining a Luenberger-like reduced-order observer with an interval observer to handle both sensor and actuator faults.\"},{\"question\":\"How does the scheme deal with both sensor and actuator faults simultaneously?\",\"answer\":\"It introduces an output transformation to decouple the sensor fault, and forms a multiple unknown input to address external disturbance and actuator fault, then designs observers to reconstruct these components.\"},{\"question\":\"What guarantees stability and theoretical properties of the fault-tolerant control scheme?\",\"answer\":\"The closed-loop system is shown to be asymptotically stable under simultaneous sensor and actuator faults, and the observer-based FTC mechanism satisfies the separation principle.\"}]","Active Compensation Fault-Tolerant Control for Uncertain Systems with Both Actuator and Sensor Faults | PDF",1790767506,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f545456189066a45fc93e48859d45247.webp",983,1390,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f5afed9657ab273bd6700fdb484dcfe6.webp",982,1388,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b729d855b841d60ccf897480078673f7.webp",981,1387,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ce4427e77c240aac0744f9d2b30eff75.webp",980,1385]