[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-646057-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-646057-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","ach580-34-drive-modules-quick-installation-guide","ACH580-34 drive modules - Quick installation guide","","Quick installation guide for ACH580-34 drive modules, providing concise steps to install the drive module into a 800 mm wide Rittal VX25 cabinet. Covers key safety requirements before beginning work, including handling precautions, electrical isolation procedures, and discharge waiting time. Includes guidance on selecting power cables, ensuring cooling and allowed operating temperature range, and protecting the drive and input power cables. Provides step-by-step installation actions for integrating the drive module and, where applicable, an LCL filter module into the cabinet, plus references to safety figures and other relevant manuals.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/ach580-34-drive-modules-quick-installation-guide/646057/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/ach580-34-drive-modules-quick-installation-guide/646057.png","ImageObject",300,407,{"name":42,"@type":43},"xXChrisXx","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-12","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What safety checks must be completed before starting installation or maintenance?","Question",{"text":63,"@type":64},"Clearly identify the work location, disconnect all possible voltage sources, lock disconnectors in the open position, protect other energized parts, and allow 5 minutes for intermediate circuit capacitors to discharge.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How should the drive module be handled to prevent tipping or falling?",{"text":68,"@type":64},"Handle carefully without tilting beyond 5 degrees, do not leave it unattended on a sloping floor, and attach top lifting lugs with chains to the cabinet frame before pushing it into the cabinet.",{"name":70,"@type":61,"acceptedAnswer":71},"What temperature range is allowed without derating, and what should be ensured for cooling?",{"text":72,"@type":64},"Maintain an allowed operating temperature range of -15 to +40℃ without derating, and use the specified cooling air flow and losses referenced in the table on page 9.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},646057,1792747247,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":108,"slug":109},7,40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":107,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":80,"read_time":144,"preview_page_count":4},8796112263567,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","# ACH580-34 drive modulesQuick installation guide\n\nEnglish........3  \n## List of related manuals\n\n        Code(English)           Drive/converter/inverter safety instructionsMultilingual code:3AXD50000037978ACH580-34 drive modules hardware manual3AXD50000419708ACH580-34 drive modules quick installation guide3AXD50000424627ACx-AP-x Assistant control panels user's manual3AUA0000085685Recycling instructions and environmental information3AXD50000137688for ACS880-04,ACS880-14,ACS880-34,ACS580-04,ACQ580-04 and ACH580-04 drives  \nDrive hardware manuals and guides  \nDrive firmware manuals and guides                             \nACH580 HVAC control program firmware manual3AXD50000027537ACH580 drives with HVAC control program quick3AXD50000047658startup guide  \nOption manuals and guides                                 \nDPMP-02/03 mounting platform for control panelsinstallation guide  \n3AUA0000136205  \nCPTC-02 ATEX-certified thermistor protection module,ExⅡ(2)GD(+L537+Q971)user's manualFOCH du/dt filters hardware manualSine filters hardware manual  \n3AXD50000030058  \n3AFE68577519  \n3AXD50000016814  \nManuals and quick guides for I/O extension modules,fieldbus adapters,etc.  \nYou can find manuals and other product documents in PDF format on the Internet.See sectionDocument library on the Internet on the inside of the back cover.For manuals not available in theDocument library,contact your local ABB representative.  \nThe code below opens an online listing of the manuals applicable to the product:  \nACH580-34 manuals  \n3AXD50000424627 Rev CMUL  \nEFFECTIVE:2019-09-12◎ 2019 ABB Oy.All Rights Reserved.  \n## EN-Quick installation guide\n\n### Contents of this guide\n\nThis guide tells you briefly how to install the drive module into a 800 mm wide Rittal VX25cabinet.For installation examples in different cabinets and more detailed instructions,engineering guide lines,technical data and complete safety instructions,see the hardwaremanual (www.abb.com/drives,Select Document Library and search for document number3AXD50000419708 [English]).  \n### Obey the safety instructions\n\nSee figures on page 9.If you ignore these instructions,injury or death,or damage to theequipment can occur.  \nWARNING!Handle the drive module carefully.Open the support legs by pressingeach leg a little down and turning it aside (1,2).  \nDo not tilt the drive module.It is heavy and its center of gravity is high.Themodule willoverturn from a sideways tilt of 5 degrees.Do not leave the moduleunattended on a sloping floor.  \nTo prevent the drive module from falling,attach its top lifting lugs with chains to the cabinetframe before you push the module into the cabinet.Work carefully preferably with helpfrom another person.Keep a constant pressure with one foot on the base of the module toprevent the module from falling on its back.  \nWARNING!If you are not a qualified electrical professional,do not do installationor maintenance work.Go through these steps before you begin any installation ormaintenance work.  \n1.Clearly identify the work location.  \n2.Disconnect all possible voltage sources.  \n·  Open the main disconnector of the drive.  \n·Make sure that reconnection is not possible.Lock the disconnectors to openposition and attach a warning notice to them.  \n·  Disconnect any external power sources from the control circuits before you dowork on the control cables.  \n·  After you disconnect the drive,always wait for 5 minutes to let the intermediatecircuit capacitors discharge before you continue.  \n3.Protect any other energized parts in the work location against contact.  \n4.Take special precautions when close to bare conductors.  \n### 4 EN-Quick installation guide\n\n5.Measure that the installation is de-energized.  \n·  Use a multimeter with an impedance of at least 1 Mohm.  \n·Make sure that the voltage between the drive module input power terminals(L1/U1,L2/N1,L3/W1)and the grounding(PE)busbar is close to OV.  \n·  Make sure that the voltage between the drive module UDC+and UDC-termina","cbCaikPfRuXTTC7D","https://ap.wps.com/l/cbCaikPfRuXTTC7D","pdf",11846801,22,"English","# List of related manuals\n## EN-Quick installation guide\n### Contents of this guide\n### Obey the safety instructions\n## Select the power cables\n## Ensure the cooling","[{\"question\":\"What safety checks must be completed before starting installation or maintenance?\",\"answer\":\"Clearly identify the work location, disconnect all possible voltage sources, lock disconnectors in the open position, protect other energized parts, and allow 5 minutes for intermediate circuit capacitors to discharge.\"},{\"question\":\"How should the drive module be handled to prevent tipping or falling?\",\"answer\":\"Handle carefully without tilting beyond 5 degrees, do not leave it unattended on a sloping floor, and attach top lifting lugs with chains to the cabinet frame before pushing it into the cabinet.\"},{\"question\":\"What temperature range is allowed without derating, and what should be ensured for cooling?\",\"answer\":\"Maintain an allowed operating temperature range of -15 to +40℃ without derating, and use the specified cooling air flow and losses referenced in the table on page 9.\"}]","ACH580-34 drive modules - Quick installation guide | PDF",55]