[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-394059-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-394059-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","ablation-test-case-series-numerical-simulation-of-ablative-material-response-code-and-model-comparisons","Ablation test-case series - Numerical Simulation of Ablative-Material Response - Code and Model Comparisons","","Version 2.0 (February 2014) outlines Ablation test-case series #3, aimed at comparing numerical simulation codes for ablative-material response. It describes the series’ purpose: assessing 2D-axisymmetric and 3D modeling capabilities and evaluating multidimensional effects. The document reuses TACOT material properties with an extended pressure and B0g range, explains how series #1 and #2 differed in boundary conditions and recession handling, and summarizes prior comparison outcomes, including sensitivity to thermodynamics and algorithms.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/ablation-test-case-series-numerical-simulation-of-ablative-material-response-code-and-model-comparisons/394059/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/ablation-test-case-series-numerical-simulation-of-ablative-material-response-code-and-model-comparisons/394059.png","ImageObject",300,407,{"name":42,"@type":43},"Kyle","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-31","2026-09-26",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the main goal of Ablation test-case series #3?","Question",{"text":63,"@type":64},"To test participating codes’ 2D-axisymmetric and 3D modeling capabilities and assess multidimensional effects for ablative-material response.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which material properties do the tests in series #3 use?",{"text":68,"@type":64},"The tests reuse TACOT material properties, extended to a wider pressure and B0g range compared with the previous series.",{"name":70,"@type":61,"acceptedAnswer":71},"How did earlier test cases set up comparisons, and what were the key takeaways?",{"text":72,"@type":64},"Series #1 focused on fixed surface temperature with no recession, while series #2 used a convective boundary condition and allowed surface recession. Results for type-1 and type-2 codes were mostly below 1% for temperature in the first series, while the second series showed sensitivities in the ablation-rate-related case due to thermodynamics data and algorithms.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},394059,1790867780,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":127,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":33,"preview_urls":145},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Version 2.0, February, 2014  \nAblation test-case series \\#3  \n-Numerical simulation of ablative-material response: code and model comparisons  \nTom van Eekelen 􀀃 Alexandre Martin y Jean Lachaud z Daniele Bianchi x  \nI. Introduction  \nCode developers and users are curious to see \"how their code compares\" and \"what are the eﬀects of the diﬀerent hypotheses in the models implemented\". In 2011, an eﬀort was started to allow such comparisons for ablative material response codes and models, in an open forum. Since then, each year, a test-case series has been proposed within the framework of the NASA/AFOSR/SNL ablation workshop-around February, each year. This year, it is targeted to release the ﬁnal version of the test-case in the timeframe of the 6th Ablation Workshop at the University of Illinois (10-11 April 2014) . The test-case series are designed to propose problems of increasing complexity. Each series tackles only a few aspects of the material response to allow a targeted comparison of the codes and of the models. The ﬁrst test-case was mostly a heat transfer problem chosen for it's simplicity, allowing to set the focus on the in-depth material response (it is summarized in section I.A) . The second test-case series went one step further and made use of a convective boundary condition-as in state-of-the-art design codes and reached the state-of-the-art (see section I.B) . This document presents the third series. The main goal of this new series, is to test the 2D-axisymmetrical and 3D modeling capabilities of the participating codes and assess multidimensional eﬀects. All tests within test-case series \\#3 re-use the TACOT material properties (but with an extended pressure and B0g range) deﬁned for the previous series.2  \nI.A. Summary of the ﬁrst test-case  \nThe ﬁrst test case was deﬁned for the 4th Ablation Workshop, 1-3 March 2011, Albuquerque, New Mexico.1 It is a one-dimensional test-case focusing on the in-depth material response- ﬁxed surface temperature and no recession. Three types of material-response codes have been identiﬁed during this ﬁrst comparison:  \n􀀏 Type 1: based on the CMA4 model or any mathematically equivalent model (heat transfer, pyrolysis, simpliﬁed mass transport);  \n􀀏 Type 2: CMA-type + Averaged momentum equation for the transport of the pyrolysis gases;  \n􀀏 Type 3: Higher ﬁdelity codes (chemical/thermal non-equilibrium, etc) .  \nThe results had been provided by the participants before the workshop and a summary was presented during the workshop.3 For type 1 and type 2 codes, diﬀerences in the temperature prediction were mostly below 1% . Type-3 code results were more scattered but they were mostly based on heuristic models that will need further validation.  \nI.B. Summary of the second test-case series  \nThe deﬁnition of the test case series \\#2 was ﬁnalized in January 2012 .2 The second test-case series aims at reaching the state-of-the-art TPS-design level. For consistency with test-case series \\#1 and to limit time-investment, most of the parameters and boundary conditions are unchanged. The main modiﬁcations are: (1) convective boundary condition (instead of ﬁxed surface-temperature boundary condition), and (2) surface recession is allowed. Computing the ablation rate to obtain the amount of surface recession is a  \n􀀃 Tom.vanEekelen@lmsintl.com[y](yAlexandre.Martin@uky.edu)[Alexandre.Martin@uky.edu](yAlexandre.Martin@uky.edu)[ ](yAlexandre.Martin@uky.edu)[z](zjlachaud@ucsc.edu)[jlachaud@ucsc.edu](zjlachaud@ucsc.edu)[ ](zjlachaud@ucsc.edu)[x](xDaniele.Bianchi@uniroma1.it)[Daniele.Bianchi@uniroma1.it](xDaniele.Bianchi@uniroma1.it)  \n1 of 19  \nAblation test-case series \\# 3-Version 2.0, February, 2014  \ncomplicated and still open problem. A traditional B' table is provided to facilitate the in-depth materialresponse comparison but other tables/methods may be used. A speciﬁc test-case dedicated to the estimation of the ablation rate is also proposed. Therefore, the test-case series \\#2 includes thr","cbCaiuZwntLptZck","https://ap.wps.com/l/cbCaiuZwntLptZck","pdf",6207052,"English","# I. Introduction\n## I.A. Summary of the first test-case\n## I.B. Summary of the second test-case series\n# II. Description of the third test-case series","[{\"question\":\"What is the main goal of Ablation test-case series #3?\",\"answer\":\"To test participating codes’ 2D-axisymmetric and 3D modeling capabilities and assess multidimensional effects for ablative-material response.\"},{\"question\":\"Which material properties do the tests in series #3 use?\",\"answer\":\"The tests reuse TACOT material properties, extended to a wider pressure and B0g range compared with the previous series.\"},{\"question\":\"How did earlier test cases set up comparisons, and what were the key takeaways?\",\"answer\":\"Series #1 focused on fixed surface temperature with no recession, while series #2 used a convective boundary condition and allowed surface recession. Results for type-1 and type-2 codes were mostly below 1% for temperature in the first series, while the second series showed sensitivities in the ablation-rate-related case due to thermodynamics data and algorithms.\"}]","Ablation test-case series - Numerical Simulation of Ablative-Material Response - Code and Model Comparisons | PDF",1790398219,48,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/bb2f8e9910c0ceb8087450456009aa40.webp",983,1272,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c4ae3e44bf3df11e345abdcd9a4e04ac.webp",982,1270,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/282c2353be3701d3d406b1aebdf83074.webp",981,1269,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/7995011774f7d74bc167cdaa694db2b4.webp",980,1268]