[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-345570-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-345570-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","a-nir-iib-excited-capsule-endoscope-enabling-high-contrast-fluorescence-imaging-via-spectrally-isolated-detection-for-early-stage-gastrointestinal-cancer","A NIR-IIb-excited capsule endoscope - enabling high-contrast fluorescence imaging via spectrally-isolated detection for early-stage gastrointestinal cancer","","Early detection of gastrointestinal cancers is hindered by invasive wired endoscopes, limited penetration of white-light capsule endoscopy, and weak fluorescence signal contrast caused by excitation-light interference in conventional imaging. This work develops a near-infrared-IIb (NIR-IIb) window-excited capsule endoscope (FICE) for high-contrast imaging of early-stage lesions. A 1550-nm laser diode shapes excitation for selective activation of upconversion nanoprobes, producing 540 nm fluorescence with strong SNR and contrast by spectral separation of excitation and emission. Proof-of-concept in nude mice shows fluorescence detection of subcutaneous and colonic mucosal tumors up to 6 mm depth with >90% fluorescence-to-background contrast, supported by ex vivo porcine validation and a wireless power and posture control system, highlighting clinical potential.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/a-nir-iib-excited-capsule-endoscope-enabling-high-contrast-fluorescence-imaging-via-spectrally-isolated-detection-for-early-stage-gastrointestinal-cancer/345570/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/a-nir-iib-excited-capsule-endoscope-enabling-high-contrast-fluorescence-imaging-via-spectrally-isolated-detection-for-early-stage-gastrointestinal-cancer/345570.png","ImageObject",300,407,{"name":42,"@type":43},"Riley","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-23","2026-09-22",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",17,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What problem does the NIR-IIb-excited capsule endoscope address in early gastrointestinal cancer detection?","Question",{"text":63,"@type":64},"It targets challenges from invasive wired endoscopes, limited tissue penetration of white-light capsule endoscopy, and low SNR/contrast caused by excitation-light interference in traditional fluorescence capsule imaging.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How does the FICE improve fluorescence imaging contrast and signal-to-noise ratio?",{"text":68,"@type":64},"It uses a 1550-nm NIR-IIb laser to excite upconversion nanoprobes in lesion tissues and relies on spectral separation of more than 1000 nm between excitation and emission to eliminate background interference.",{"name":70,"@type":61,"acceptedAnswer":71},"What validation results support the FICE’s performance?",{"text":72,"@type":64},"In nude mice, it detected fluorescence from subcutaneous and colonic mucosal tumors with penetration depth up to 6 mm and fluorescence-to-background contrast ratios exceeding 90%. Ex vivo porcine tissue experiments further confirmed imaging capability in realistic anatomical settings.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},345570,1790515419,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":128,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},1374391975076,"https://ap-avatar.wpscdn.com/avatar/14000253ca4ec9f6853?x-image-process=image/resize,m_fixed,w_180,h_180&k=1783305029341752051","Wang et al. Journal of Nanobiotechnology (2026) 24:545 Journal of Nanobiotechnology  \n[https://doi.org/10.1186/s12951-026-04298-1](https://doi.org/10.1186/s12951-026-04298-1)  \nRESEARCH Open Access  \nA NIR-IIb-excited capsule endoscope enabling  high-contrast fluorescence imaging viaspectrally-isolated detection for early-stage gastrointestinal cancer  \nWeicheng Wang1, Qichao Li3*, YumingYang1,7, Wei Wang1, Jinlei Jiang1, Mianyi Xiang1, Chunlei Jiang4, Qirui Zhao2, Xinyuan Cui5, Shengsheng Cui1, Ning Tang1,6, Binyu Zhu1, Mingrui Chen1, Yongyi Xu1, Cheng Zhou1* and Daxiang Cui1,2*  \nAbstract  \nEarly detection of gastrointestinal cancers faces significant challenges, mainly including the invasiveness of wired endoscopes, the limited tissue penetration depth of white light capsule endoscopy (CE), and the low signal  \nto-noise ratio (SNR) and contrast caused by excitation light interference in traditional fluorescence imaging CE. Herein, we developed a near-infrared-IIb (NIR-IIb) window-excited fluorescence imaging capsule endoscope (FICE) for the high-contrast diagnosis of early-stage gastrointestinal cancers. The FICE employs a 1550-nm central wavelength NIR-IIb laser diode to precisely shape the excitation beam for selective activation of upconversion nanoprobes (UCNPs) aggregates in lesion tissues, stimulating them to emit 540 nm green fluorescence—the most sensitive wavelength for CMOS imaging chips. Utilizing 1550 nm excitation light facilitates enhanced penetration into biological tissues and the detection method with an excitation-emission spectral separation of more than 1000 nm effectively eliminates background interference, thereby yielding diagnostic images with ultrahigh SNRand superior contrast. Proof-of-concept experiments in nude mice demonstrated that this FICE achieved specific fluorescence detection of subcutaneous and colonic mucosal tumors with a penetration depth of up to 6 mm and fluorescence-to-background contrast ratios exceeding 90% . Ex vivo validation in porcine tissues confirmed the FICE’s imaging capability within realistic anatomical environments. Furthermore, we designed a wireless power supply and posture control system to provide continuous energy and precise motion control for the FICE. To our knowledge, this paper presents the first NIR-IIb-excited FICE, offering a non-invasive, high-contrast and high-SNR diagnostic tool for early gastrointestinal cancer detection and demonstrating remarkable clinical potential.  \n*Correspondence: Qichao Li[liqichao@sjtu.edu.cn](liqichao@sjtu.edu.cn)[ ](liqichao@sjtu.edu.cn)Cheng Zhou [zhou-cheng@sjtu.edu.cn](zhou-cheng@sjtu.edu.cn)[ ](zhou-cheng@sjtu.edu.cn)Daxiang Cui [dxcui@sjtu.edu.cn](dxcui@sjtu.edu.cn)  \nFull list of author information is available at the end of the article  \n© The Author(s) 2026. Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit [http://creati](http://creati)[vecommons.org/licenses/by-nc-nd/4.0/](vecommons.org/licenses/by-nc-nd/4.0/.)[.](vecommons.org/licenses/by-nc-nd/4.0/.)  \nWang et al. Journal of Nanobiotechnology (2026) 24:545 Pa","cbCaiodl2NlPzSvu","https://ap.wps.com/l/cbCaiodl2NlPzSvu","pdf",5782347,"English","# Introduction\n## Background and clinical need\n## Limitations of existing endoscopy and capsule endoscopy\n## Rationale for NIR-IIb fluorescence and spectral isolation","[{\"question\":\"What problem does the NIR-IIb-excited capsule endoscope address in early gastrointestinal cancer detection?\",\"answer\":\"It targets challenges from invasive wired endoscopes, limited tissue penetration of white-light capsule endoscopy, and low SNR/contrast caused by excitation-light interference in traditional fluorescence capsule imaging.\"},{\"question\":\"How does the FICE improve fluorescence imaging contrast and signal-to-noise ratio?\",\"answer\":\"It uses a 1550-nm NIR-IIb laser to excite upconversion nanoprobes in lesion tissues and relies on spectral separation of more than 1000 nm between excitation and emission to eliminate background interference.\"},{\"question\":\"What validation results support the FICE’s performance?\",\"answer\":\"In nude mice, it detected fluorescence from subcutaneous and colonic mucosal tumors with penetration depth up to 6 mm and fluorescence-to-background contrast ratios exceeding 90%. Ex vivo porcine tissue experiments further confirmed imaging capability in realistic anatomical settings.\"}]","A NIR-IIb-excited capsule endoscope - enabling high-contrast fluorescence imaging via spectrally-isolated detection for early-stage gastrointestinal cancer | PDF",1790058143,48,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/757fdc6c88a05d4db15ff16eb2666a19.webp",983,1310,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3ea25e816cfb8de7dc0c5ae751d24f1e.webp",982,1309,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/e386b1e33100370ded605014ee16e852.webp",981,1308,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/dd68d90e515ec46f8ad1ea1d531775e3.webp",980,1306]