[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-467835-105":59,"doc-detail-467835-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","a-natural-gas-energy-metering-method-based-on-density-sound-velocity-correlation","A Natural Gas Energy Metering Method Based on Density-Sound Velocity Correlation","","This paper proposes a natural gas energy metering method using the correlation between gas density and sound velocity. The approach combines physical-property correlation models with measured operating parameters—temperature, pressure, sound velocity, and density—to predict the compression factor and the ideal volume calorific value. Volume flow is corrected via the compression factor to compute accurate metering results. A 10,000-sample dataset supports machine-learning model training and testing, and a range-based model-switching strategy improves accuracy, validated on a real-flow test bench.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/a-natural-gas-energy-metering-method-based-on-density-sound-velocity-correlation/467835/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/a-natural-gas-energy-metering-method-based-on-density-sound-velocity-correlation/467835.png","ImageObject",300,407,{"name":92,"@type":93},"acoobca","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the core idea of the proposed natural gas energy metering method?","Question",{"text":113,"@type":114},"It meters natural gas energy by exploiting the correlation between density and sound velocity, together with measured operating parameters.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Which quantities does the method use to predict the compression factor and calorific value?",{"text":118,"@type":114},"It uses temperature, pressure, sound velocity, and density within physical-property correlation models, then applies machine learning to build predictive models.",{"name":120,"@type":111,"acceptedAnswer":121},"How is the method validated and what accuracy is reported?",{"text":122,"@type":114},"The method is validated using a natural gas real-flow test bench, showing maximum prediction errors of 0.061% for the compression factor and 1.19% for the calorific value, with up to 1.21% relative energy error across four gas samples.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},467835,1790982613,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},3985747870733,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Article  \nA Natural Gas Energy Metering Method Based on DensitySound Velocity Correlation  \nBin Zhang 1, Zhenwei Huang 1,*, Wenlin Wang 2, Junxian Wang 3, Dailiang Xie 1, Ying Cheng 1 and Yi Yang 1  \nAcademic Editor: Erwin Peiner  \nReceived: 15 November 2025  \nRevised: 25 December 2025  \nAccepted: 31 December 2025  \nPublished: 5 January 2026  \nCopyright: © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China; [p23020854125@cjlu.edu.cn](p23020854125@cjlu.edu.cn) (B.Z.); [dlxie@cjlu.edu.cn](dlxie@cjlu.edu.cn) (D.X.); [p23020854004@cjlu.edu.cn](p23020854004@cjlu.edu.cn) (Y.C.); [p24020854140@cjlu.edu.cn](p24020854140@cjlu.edu.cn) (Y.Y.)  \n2 Flow and Energy Metrology & Testing Institute, Energy Environment and Life Health Metrology Center, Zhejiang Institute of Quality Sciences, Hangzhou 310018, China; [wangwenlin111@163.com](wangwenlin111@163.com)  \n[3](3 College of Metrology & Measurement Engineering)[ College of Metrology & Measurement Engineering](3 College of Metrology & Measurement Engineering), [China Jiliang University College of Modern Science and](China Jiliang University College of Modern Science and)[ ](China Jiliang University College of Modern Science and)Technology, Yiwu 322002, China; [wangjunxian@cjlu.edu.cn](wangjunxian@cjlu.edu.cn)  \n* Correspondence: [19a1802041@cjlu.edu.cn](19a1802041@cjlu.edu.cn); Tel.: +86-136-1655-9047  \nAbstract  \nThis paper proposes a method for metering natural gas energy based on the correlation between density and sound velocity. The technique integrates physical property correlation models with measured parameters, such as temperature, pressure, sound velocity, and density, to accurately predict the compression factor and the ideal volume calorific value of natural gas under operating conditions. The volume flow is corrected using the compression factor, which enables precise metering of natural gas energy through the adjusted volume flow and calorific value. To develop a high-precision physical property correlation model, a natural gas dataset comprising 10,000 sample sets is first constructed for model training and testing. Multiple machine learning algorithms are then employed to build predictive models. Analysis of the experimental results led to the development of a model-switching strategy based on the ranges of input features, which substantially enhanced prediction accuracy. For the compression factor model, the mean absolute error (MAE), root mean square error (RMSE), mean absolute percentage error (MAPE), and coefficient of determination (R2 ) were 0.00118, 0.0030, 0.14%, and 0.9987, respectively. The corresponding indicators for the calorific value model were 0.1583, 0.331, 0.44%, and 0.9736 . The proposed method is finally validated using a natural gas real-flow test bench. The results demonstrated maximum prediction errors of 0.061% and 1.19% for the compression factor and calorific value, respectively, while the maximum relative energy error across four gas samples was 1.21% . These results indicate that the method can effectively achieve accurate natural gas energy metering in practical operating conditions.  \nKeywords: natural gas; energy metering; calorific value; physical property correlation; compression factor; machine learning; model switching; real-flow validation  \n1. Introduction  \nEnergy metering, which accounts for both the quality and quantity of natural gas, has gradually become the mainstream method for settlement in natural gas trading [1,2] . Accurate measurement of natural gas volume and calorific value is critical to ensuring the reliability of energy metering [3,4] . However, factors such as temperature, pressure, composition, and the proportion of each component in natural gas can influence its volume and calorific","cbCailseY5REMYqi","https://ap.wps.com/l/cbCailseY5REMYqi","pdf",9932639,25,"English","# Abstract\n# Keywords\n# 1. Introduction","[{\"question\":\"What is the core idea of the proposed natural gas energy metering method?\",\"answer\":\"It meters natural gas energy by exploiting the correlation between density and sound velocity, together with measured operating parameters.\"},{\"question\":\"Which quantities does the method use to predict the compression factor and calorific value?\",\"answer\":\"It uses temperature, pressure, sound velocity, and density within physical-property correlation models, then applies machine learning to build predictive models.\"},{\"question\":\"How is the method validated and what accuracy is reported?\",\"answer\":\"The method is validated using a natural gas real-flow test bench, showing maximum prediction errors of 0.061% for the compression factor and 1.19% for the calorific value, with up to 1.21% relative energy error across four gas samples.\"}]","A Natural Gas Energy Metering Method Based on Density-Sound Velocity Correlation | PDF",1790773448,63,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/faf968c45bd28deb51bd35606756a498.webp",983,1390,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e7e853c3f8ab24c792a79aa6489b95e4.webp",982,1388,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f2280343f66f24a34d790f519621c314.webp",981,1387,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/78f09a8677c0019aaa02ce1f839d20f3.webp",980,1385]