[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-463542-105":59,"doc-detail-463542-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","a-linear-and-high-sensitivity-microwave-biosensor-on-a-fr-4-substrate-for-aqueous-glucose-monitoring-using-a-concentric-square-shaped-split-ring-resonator","A Linear and High-Sensitivity Microwave Biosensor on a FR-4 Substrate for Aqueous Glucose Monitoring Using a Concentric Square-Shaped Split-Ring Resonator","","Non-invasive glucose monitoring remains a significant challenge in diabetes management, with existing approaches often limited by poor accuracy, high cost, or patient discomfort. Microwave-based biosensors offer a promising label-free alternative by exploiting the dielectric contrast between glucose and water. This paper presents a compact, dualband concentric square-shaped split-ring resonator biosensor on a low-cost FR-4 substrate, converting glucose permittivity changes into resonance-frequency and reflection-coefficient shifts for quantitative aqueous detection up to 250 mg/dL.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/a-linear-and-high-sensitivity-microwave-biosensor-on-a-fr-4-substrate-for-aqueous-glucose-monitoring-using-a-concentric-square-shaped-split-ring-resonator/463542/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/a-linear-and-high-sensitivity-microwave-biosensor-on-a-fr-4-substrate-for-aqueous-glucose-monitoring-using-a-concentric-square-shaped-split-ring-resonator/463542.png","ImageObject",300,407,{"name":92,"@type":93},"kopisore","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is non-invasive glucose monitoring difficult in diabetes care?","Question",{"text":112,"@type":113},"Existing methods are often limited by insufficient accuracy, high cost, and discomfort for patients, making consistent monitoring challenging.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the proposed microwave biosensor detect aqueous glucose?",{"text":117,"@type":113},"It uses a concentric square-shaped split-ring resonator to translate glucose-induced permittivity changes into measurable shifts in resonance frequency and reflection coefficient.",{"name":119,"@type":110,"acceptedAnswer":120},"What sensing performance does the paper report for the glucose range?",{"text":121,"@type":113},"Experiments show a linear, monotonic response up to 250 mg/dL, with reported frequency-domain sensitivity and amplitude-domain sensitivity along with high determination coefficients.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},463542,1791259057,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962090880963,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Article  \nA Linear and High-Sensitivity Microwave Biosensor on a FR-4 Substrate for Aqueous Glucose Monitoring Using a Concentric Square-Shaped Split-Ring Resonator  \nKhouloud Jomaa 1, Sehmi Saad 2, *, Darine Kaddour 3, Pierre Lemaître-Auger 3 and Hatem Garrab 1,4  \nAcademic Editor: Emanuele Piuzzi  \nReceived: 15 November 2025  \nRevised: 18 December 2025  \nAccepted: 22 December 2025  \nPublished: 24 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Electronics and Micro-Electronic Laboratory (LEµE), Bd de L’environnement, Monastir 5000, Tunisia; [khouloudjomaa1@gmail.com](khouloudjomaa1@gmail.com) (K.J.); [garhat@yahoo.fr](garhat@yahoo.fr) (H.G.)  \n2 RF2S Spectrum Solutions, 18 Street of the Faïencerie, 33300 Bordeaux, France  \n3 University Grenoble-Alpes, Grenoble-INP/LCIS, 26000 Valence, France;  \n[darine.kaddour@lcis.grenoble-inp.fr](darine.kaddour@lcis.grenoble-inp.fr) (D.K.); [pierre.lemaitre-auger@lcis.grenoble-inp.fr](pierre.lemaitre-auger@lcis.grenoble-inp.fr) (P.L.-A.)  \n4 Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, Street Taher Ben Achour, Sousse 4003, Tunisia  \n* Correspondence: [sehmi.saad@gmail.com](sehmi.saad@gmail.com); Tel.: +33-758326157  \nAbstract  \nNon-invasive glucose monitoring remains a significant challenge in diabetes management, with existing approaches often limited by poor accuracy, high cost, or patient discomfort. Microwave-based biosensors offer a promising label-free alternative by exploiting the dielectric contrast between glucose and water. This paper presents a compact, dualband concentric square-shaped split-ring resonator (SRR-type) biosensor fabricated on a low-cost FR-4 substrate for aqueous glucose detection. The sensor leverages electric field confinement in inter-ring gaps to transduce glucose-induced permittivity changes into measurable shifts in resonance frequency and reflection coefficient. Experimental results demonstrate a linear, monotonic response across the clinical range up to 250 mg/dL, with a frequency-domain sensitivity of 1.964 MHz/(mg/dL) and amplitude-domain sensitivity of 0.0332 dB/(mg/dL), achieving high coefficients of determination (R2 = 0.9956 and 0.9927, respectively). The design achieves a normalized size of 0.137 λg2, combining high sensitivity and compact size within a scalable platform. Operating in the UWB-adjacent band (2.76–3.25 GHz), the proposed biosensor provides a practical, reproducible, and PCBcompatible solution for next-generation label-free glucose monitoring.  \nKeywords: microwave biosensor; split-ring resonator (SRR); planar biosensor; label-free glucose sensing; diabetes; ultra-wideband (UWB) biosensing  \n1. Introduction  \nDiabetes mellitus (DM) is a chronic metabolic disorder characterized by persistent hyperglycemia resulting from defects in insulin secretion, insulin action, or both. It represents a major and growing global health challenge: the number of adults living with diabetes rose from 422 million in 2014 to 537 million in 2021 and is projected to reach 643 million by 2030 and 783 million by 2045 [1] . DM encompasses several subtypes with distinct etiologies and clinical trajectories. Type 1 diabetes (T1D) arises from autoimmune destruction of pancreatic β-cells, leading to absolute insulin deficiency, typically diagnosed in childhood or adolescence. Type 2 diabetes (T2D), the most prevalent form, stems from a combination of insulin resistance and progressive β-cell dysfunction and is increasingly observed in younger populations due to rising obesity and sedentary lifestyles. Additional  \nforms include gestational diabetes mellitus (GDM), monogenic diabetes syndromes, cystic fibrosis–related diabetes (CFRD), and drug-or chemical-induced diabetes [1,2] . This heterogeneity underscores the need for personalized, accurate, and fr","cbCaievEDYWBIVZt","https://ap.wps.com/l/cbCaievEDYWBIVZt","pdf",3656347,21,"English","# Abstract\n# Keywords\n# 1. Introduction","[{\"question\":\"Why is non-invasive glucose monitoring difficult in diabetes care?\",\"answer\":\"Existing methods are often limited by insufficient accuracy, high cost, and discomfort for patients, making consistent monitoring challenging.\"},{\"question\":\"How does the proposed microwave biosensor detect aqueous glucose?\",\"answer\":\"It uses a concentric square-shaped split-ring resonator to translate glucose-induced permittivity changes into measurable shifts in resonance frequency and reflection coefficient.\"},{\"question\":\"What sensing performance does the paper report for the glucose range?\",\"answer\":\"Experiments show a linear, monotonic response up to 250 mg/dL, with reported frequency-domain sensitivity and amplitude-domain sensitivity along with high determination coefficients.\"}]","A Linear and High-Sensitivity Microwave Biosensor on a FR-4 Substrate for Aqueous Glucose Monitoring Using a Concentric Square-Shaped Split-Ring Resonator | PDF",1790766740,53,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/718c8543a0a6d9f358a2e0d4b8caddbc.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3ac37273e4a7d6d0e8797c61cf1b8379.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/976e0aa67bcc788f33fb6a14bd83e97a.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5b205b55d9b3ef9847e1bb736eec4c51.webp",980,1385]