[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-459893-105":59,"doc-detail-459893-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","a-commentary-on-radiographic-analysis-of-endplate-coverage-of-a-3-dimensional-expandable-transforaminal-lumbar-interbody-fusion-tlif-implant-compared-to-static-tlif-and-anterior-lumbar-interbody-fusion-implants","A Commentary on “Radiographic Analysis of Endplate Coverage of a 3-Dimensional-Expandable Transforaminal Lumbar Interbody Fusion (TLIF) Implant Compared to Static TLIF and Anterior Lumbar Interbody Fusion Implants”","","Commentary discussing how implant–endplate coverage affects outcomes in lumbar interbody fusion, highlighting complications such as endplate violation, subsidence, pseudarthrosis, and construct failure. The text reviews a radiographic comparison of static TLIF, 3D-expandable TLIF, and ALIF devices, emphasizing rigorous CT-based measurement, high interobserver reliability, and multivariable analysis to isolate implant-type effects. Key results show substantially higher coverage with 3D-expandable TLIF and ALIF, with level-specific implications and biomechanical rationale for improved load distribution and stability.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/a-commentary-on-radiographic-analysis-of-endplate-coverage-of-a-3-dimensional-expandable-transforaminal-lumbar-interbody-fusion-tlif-implant-compared-to-static-tlif-and-anterior-lumbar-interbody-fusion-implants/459893/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/a-commentary-on-radiographic-analysis-of-endplate-coverage-of-a-3-dimensional-expandable-transforaminal-lumbar-interbody-fusion-tlif-implant-compared-to-static-tlif-and-anterior-lumbar-interbody-fusion-implants/459893.png","ImageObject",300,407,{"name":92,"@type":93},"Stanley","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-09","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is endplate coverage important in lumbar interbody fusion?","Question",{"text":112,"@type":113},"Inadequate coverage can predispose to endplate violation, subsidence, pseudarthrosis, and eventual construct failure, making implant–endplate interface optimization a persistent challenge.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How did the authors of the referenced radiographic study assess endplate coverage?",{"text":117,"@type":113},"They used standardized postoperative computed tomography, measuring implant and endplate dimensions and deriving coverage ratios with clear geometric approximations, supported by strong interobserver reliability and multivariable analysis.",{"name":119,"@type":110,"acceptedAnswer":120},"What were the main coverage comparisons among static TLIF, 3D-expandable TLIF, and ALIF?",{"text":121,"@type":113},"Static TLIF showed the lowest mean coverage ratio (0.18), 3D-expandable TLIF nearly doubled it (0.35), and ALIF had the highest coverage (0.46), with adjusted analyses confirming the advantage of 3D-expandable TLIF and ALIF over static TLIF.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},459893,1790757198,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":39,"preview_page_count":81,"preview_urls":143},2336477405376,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Neurospine 2025;22(4):902-904. [https://doi.org/10.14245/ns.2551806.903](https://doi.org/10.14245/ns.2551806.903)  \nNeurospine  \npISSN 2586-6583 eISSN 2586-6591  \nCommentary  \nCorresponding Author  \nXiaofeng Lian  \n [https://orcid.org/0000-0003-3857-9823](https://orcid.org/0000-0003-3857-9823)  \nDepartment of Orthopedics, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, No. 600, Yishan Road, Xuhui District, Shanghai, China  \nEmail: [lianxiaofeng@shsmu.edu.cn](lianxiaofeng@shsmu.edu.cn)  \nSee the article “Radiographic Analysis of Endplate Coverage of a 3-DimensionalExpandable Transforaminal Lumbar Interbody Fusion (TLIF) Implant Compared to Static TLIF and Anterior Lumbar Interbody Fusion Implants” via [https://doi.org/10.14245/ns.2551166.583](https://doi.org/10.14245/ns.2551166.583).  \nThis is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ([https://creativecom](https://creativecom)[mons.org/licenses/by-nc/4.0/](mons.org/licenses/by-nc/4.0/)) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.  \nCopyright © 2025 by the Korean Spinal Neurosurgery Society  \nA Commentary on “Radiographic Analysis of Endplate Coverage of a 3-Dimensional-Expandable Transforaminal Lumbar Interbody Fusion (TLIF) Implant Compared to Static TLIF and Anterior Lumbar Interbody Fusion Implants”  \nKun Wang, Xiaofeng Lian  \nDepartment of Orthopedics, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China  \nLumbar interbody fusion is a cornerstone surgical treatment for degenerative spinal conditions, yet optimizing the implant–endplate interface remains a persistent challenge.1 Inadequate endplate coverage predisposes to endplate violation, subsidence, pseudarthrosis, and construct failure.2,3 Despite decades of refinement in cage materials and geometry, a fundamental trade-off has persisted: posterior approaches offer familiar anatomy and reduced vascular risk but historically at the cost of a smaller implant footprint, whereas anterior approaches maximize endplate coverage but demand greater surgical complexity and carry approach-related morbidity.4  \nAgainst this backdrop, the radiographic study by Mazza et al.5 provides timely and muchneeded quantitative data comparing vertebral endplate coverage among static transforaminal lumbar interbody fusion (TLIF), 3-dimensional (3D)-expandable TLIF, and anterior lumbar interbody fusion (ALIF) devices. The authors hypothesized that contemporary 3Dexpandable TLIF cages, capable of in situ radial expansion, could overcome the geometric limitations of static TLIF implants and approach the endplate coverage historically achievable only by anterior cages. This study directly informs surgical decision-making when balancing approach-related risk, implant biomechanics, and patient-specific anatomy.  \nMethodologically, the authors’ approach is rigorous and reproducible. Using standardized postoperative computed tomography imaging, they measured implant and endplate dimensions and derived coverage ratios through clear geometric approximations. Interobserver reliability testing demonstrated excellent agreement, with intraclass correlation coefficients ranging from 0.97 to 0.98, strongly supporting the robustness of their measurement technique. Importantly, multivariable analysis of covariance was employed to account for anatomic variability in endplate area and surgical level, thereby isolating the independent effect of implant type on coverage ratios.  \n902 [www.e-neurospine.org](www.e-neurospine.org)  \nThe principal findings are striking and carry immediate clinical relevance. Static TLIF cages achieved a mean coverage ratio of 0.18, whereas 3D-expandable TLIF cages nearly doubled this value to 0.35. ALIF cages provided the greatest coverage at 0.46. After adjustment for","cbCaiiX1RX1KlRBJ","https://ap.wps.com/l/cbCaiiX1RX1KlRBJ","pdf",167964,"English","# Commentary context and clinical problem\n## Study design and measurement approach\n## Results and level-specific findings\n## Biomechanical and translational implications","[{\"question\":\"Why is endplate coverage important in lumbar interbody fusion?\",\"answer\":\"Inadequate coverage can predispose to endplate violation, subsidence, pseudarthrosis, and eventual construct failure, making implant–endplate interface optimization a persistent challenge.\"},{\"question\":\"How did the authors of the referenced radiographic study assess endplate coverage?\",\"answer\":\"They used standardized postoperative computed tomography, measuring implant and endplate dimensions and deriving coverage ratios with clear geometric approximations, supported by strong interobserver reliability and multivariable analysis.\"},{\"question\":\"What were the main coverage comparisons among static TLIF, 3D-expandable TLIF, and ALIF?\",\"answer\":\"Static TLIF showed the lowest mean coverage ratio (0.18), 3D-expandable TLIF nearly doubled it (0.35), and ALIF had the highest coverage (0.46), with adjusted analyses confirming the advantage of 3D-expandable TLIF and ALIF over static TLIF.\"}]","A Commentary on “Radiographic Analysis of Endplate Coverage of a 3-Dimensional-Expandable Transforaminal Lumbar Interbody Fusion (TLIF) Implant Compared to Static TLIF and Anterior Lumbar Interbody Fusion Implants” | PDF",[144,148,152],{"page_no":8,"url":145,"width":146,"height":147},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/391a5e0aff5d44c469c225828687b344.webp",983,1310,{"page_no":14,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/bd22059fc247f0f41a1f1e7a40333da8.webp",982,1309,{"page_no":81,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/611d9d59690adab0ad46792b9751b140.webp",981,1308]