[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-377337-105":59,"doc-detail-377337-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","a-cadaveric-breast-cancer-tissue-phantom-for-phase-contrast-x-ray-imaging-applications","A cadaveric breast cancer tissue phantom for phase-contrast X-ray imaging applications","","Background: As mammography X-ray imaging advances and provides higher contrast in soft tissue, reliable imaging phantoms are needed for system design and component calibration. This work develops a breast tissue phantom from cadaveric tissue to preserve biological details seen in clinical precancerous and cancerous cases while reducing production artifacts. Methods: Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into fixed tissue while maintaining the native tumor/adipose interface. Results: The tissue hybrid phantom was mounted for absorption and refraction X-ray imaging, and digital breast tomosynthesis was performed. Conclusion: Attenuation-based and refraction-based imaging suitability is confirmed.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/a-cadaveric-breast-cancer-tissue-phantom-for-phase-contrast-x-ray-imaging-applications/377337/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/a-cadaveric-breast-cancer-tissue-phantom-for-phase-contrast-x-ray-imaging-applications/377337.png","ImageObject",300,407,{"name":92,"@type":93},"Elsa","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-24","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"Why are imaging phantoms important for advanced mammography X-ray systems?","Question",{"text":113,"@type":114},"Advanced technologies require reliable phantoms for system design and component calibration, especially when higher contrast in soft tissues is targeted and artifacts must be minimized.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How was the hybrid phantom prepared in the study?",{"text":118,"@type":114},"Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into fixed cadaveric tissue, preserving the native tumor/adipose tissue interface.",{"name":120,"@type":111,"acceptedAnswer":121},"What imaging modalities were used to evaluate the phantom?",{"text":122,"@type":114},"The phantom was mounted in a clear acrylic housing for absorption and refraction X-ray imaging, and digital breast tomosynthesis was also performed.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},377337,1790814676,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},137455077381,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","DOI: 10. 1002/ame2 .12340  \nOR I G I NAL ART I C L E  \nA cadaveric breast cancer tissue phantom for phase-contrast X-ray imaging applications  \nCody C. Rounds1,2  | Chengyue Li1,2 | Wei Zhou1,2 | Kenneth M. Tichauer1,2 |  \nJovan G. Brankov1,2,3  \n1Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois, USA 2Medical Imaging Research Center, Illinois Institute of Technology, Chicago, Illinois, USA  \n3 Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, Illinois, USA  \nCorrespondence  \nJovan G. Brankov, Technology Business Center (TBC) M-103, Siegel Hall 140 3301 South Dearborn, Chicago, Illinois, USA. Email: [brankov@iit.edu](brankov@iit.edu)  \nFunding information  \nNational Institutes of Health, Grant/  \nAward Number: EB023969 and HL154687  \nAbstract  \nBackground: As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues, a need has developed for reliable imaging phantoms for use in system design and component calibration. In advanced imaging modalities such as refraction-based methods, it is critical that developed phantoms capture the biological details seen in clinical precancerous and cancerous cases while minimizing artifacts that may be caused due to phantom production. This work presents the fabrication of a breast tissue imaging phantom from cadaveric breast tissue suitable for use in both transmission and refraction-enhanced imaging systems.  \nMethods: Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into the fixed tissue while maintaining the native tumor/adipose tissue interface.  \nResults: The resulting human–murine tissue hybrid phantom was mounted on a clear acrylic housing for absorption and refraction X-ray imaging. Digital breast tomosynthesis was also performed.  \nConclusion: Both attenuation-based imaging and refraction-based imaging of the phantom are presented to confirm the suitability of this phantom's use in both imaging modalities.  \nK E Y WO R D S  \nbreast tumors, digital mammography, imaging phantoms, orthotopic animal models, phasecontrast X-ray imaging  \n1 | INTRODUCTION  \nMammography continues to be the most widely used method for screening breast cancer globally. Although it is a critical tool in the clinic, full-field digital mammography (FFDM) has a limited ability to visualize and detect malignancies and/or premalignant lesions such as microcalcifications in breast tissue.1 This is especially problematic when screening patients with dense breast tissue, where clinical  \nstudies have reported sensitivity and specificity as low as 60% . 2,3 Over the past two decades, various enhancements to traditional single-projection mammography, such as digital breast tomosynthesis (DBT), have been investigated and proposed. These different approaches to radiographic imaging have largely been successful at improving both sensitivity and specificity of breast cancer screening, with studies reporting DBT's diagnostic accuracies of more than 97% .4 A key limitation to FFDM's ability to yield high contrast across  \nThis is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.  \n© 2023 The Authors. Animal Models and Experimental Medicine published by John Wiley & Sons Australia, Ltd on behalf of The Chinese Association for Laboratory Animal Sciences.  \ndifferent types of abnormal tissue is the two-dimensional nature of the projections, where overlapping fibroglandular tissues can dramatically reduce the contrast around abnormal lesions. To combat this, DBT allows the visualization of the entire breast volume by using multiple projections across many different angles followed by tomographic reconstruction of the three-dimensional image.5 This feature allows a clinician to investigate each layer of tissu","cbCaiaKdDdHnfeL1","https://ap.wps.com/l/cbCaiaKdDdHnfeL1","pdf",1847832,"English","# Abstract\n# Introduction\n# Methods\n# Results\n# Conclusion","[{\"question\":\"Why are imaging phantoms important for advanced mammography X-ray systems?\",\"answer\":\"Advanced technologies require reliable phantoms for system design and component calibration, especially when higher contrast in soft tissues is targeted and artifacts must be minimized.\"},{\"question\":\"How was the hybrid phantom prepared in the study?\",\"answer\":\"Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into fixed cadaveric tissue, preserving the native tumor/adipose tissue interface.\"},{\"question\":\"What imaging modalities were used to evaluate the phantom?\",\"answer\":\"The phantom was mounted in a clear acrylic housing for absorption and refraction X-ray imaging, and digital breast tomosynthesis was also performed.\"}]","A cadaveric breast cancer tissue phantom for phase-contrast X-ray imaging applications | PDF",1790224373,15,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/42279c9f9213c8f7065a9dd750825fc2.webp",983,1291,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/d1c2c05d91c36789af3f0e59285a10f4.webp",982,1290,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/7ba7b17e04dcd28e20f81f86f5a4b540.webp",981,1289,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ba3f28c1df8f71c695ac0602ddf3de34.webp",980,1287]