[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-641570-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-641570-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","96v-series-installation-instructions-two-stage-communicating-gas-furnaces","96V Series - Installation Instructions - Two-Stage Communicating Gas Furnaces","","Installation instructions for 4-position condensing two-stage communicating gas furnaces in the 96V series, including ECM blower setup. Covers recommended UL and/or CSA fuel gas and CO detector usage, factory-use-only documentation references, and superseding revisions. Provides a detailed checklist and safety information, then guides location and clearance requirements, freeze protection, site selection, and field conversion procedures with conversion tables and kit materials.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/96v-series-installation-instructions-two-stage-communicating-gas-furnaces/641570/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/96v-series-installation-instructions-two-stage-communicating-gas-furnaces/641570.png","ImageObject",300,407,{"name":42,"@type":43},"Hazel","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-26","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":22},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What safety devices are recommended for installation of the 96V series furnaces?","Question",{"text":62,"@type":63},"U.L. and/or C.S.A. recognized fuel gas and CO (carbon monoxide) detectors are recommended, and installation should follow manufacturer recommendations and applicable local laws and regulations.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What topics are covered under field conversion?",{"text":67,"@type":63},"Field conversion includes general conversion instructions and tips, lists of materials for parts bags and conversion kits, conversion table contents, and multiple installation orientations (e.g., upflow, downflow, and horizontal configurations).",{"name":69,"@type":60,"acceptedAnswer":70},"Which diagnostics areas are included for troubleshooting?",{"text":71,"@type":63},"Diagnostics and troubleshooting include standard operation codes, fault codes with descriptions and solutions, lockout procedures, guidance for replacing the furnace control, and diagnosing blower motor issues.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},641570,1793030783,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145},137441390410,"https://ap-avatar.wpscdn.com/avatar/2000252f4ab5702993?_k=1776741390130283984","INSTALLATION INSTRUCTIONS FOR 4 POSITION CONDENSING TWO-STAGE, COMMUNICATING GAS FURNACES W/ECM BLOWER  \n(-)96V SERIES  \n[U.L. and/or](U.L. and/or) C.S.A. recognized fuel gas and CO (carbon monoxide) detectors are rec-ommended inall applications, and their installation shouldbe inaccordance with the  manufacturer’srecommendationsand/orlocallaws, rules, regulations, or customs.  \n􀀀 Factory Use Only  \n92-24161-124-01  \nSUPERSEDES 92-24161-124-00  \nTABLE OF CONTENTS  \nContents  \n1 TABLE OF CONTENTS....................... 2  \n2 GENERAL INFORMATION .................... 3  \nReceiving .................................. 4  \nCalifornia Proposition 65 Note .................. 4  \nChecklist ................................... 5  \n3 SAFETY INFORMATION ...................... 6  \nWarnings ................................... 6  \nImportant Information About Efficiency and Quality.. 7  \nCommonwealth of Massachusetts Note .......... 8  \n4 LOCATION REQUIREMENTS ................. 9  \nFreeze Protection ............................ 9  \nSite Selection .............................. 10  \nClearance Accessibility ....................... 10  \nClearance Table ............................ 11  \n5 FIELD CONVERSION ....................... 12  \nGeneral Conversion Instructions and Tips ........ 12  \nLists of Materials for Parts Bag and Conversion Kits ............................ 13  \nConversion Table of Contents ................. 14  \nUpflow with Vertical Vent ................... 15-16  \nUpflow with Left Side Vent ................. 17-18  \nDownflow with Right Vent (Non Zero Clearance) 19-22  \nDownflow Zero-Clearance ................. 23-27  \nHorizontal Right with Right Vent ............. 28-30  \nHorizontal Right with Vertical Vent ........... 31-33  \nHorizontal Left with Right Vent .............. 34-38  \nHorizontal Left with Left Vent ............... 39-41  \n6 DUCTING ................................. 42  \n7 VENTING ................................. 45  \nGeneral Venting Requirements and Guidelines (All Instructions) ............................ 45  \nVenting and Combustion Air Piping Requirements ........................... 45  \nPiping Requirements ...................... 46  \nVent Pipe Sizing and Maximum Lengths .... 48-49  \nEquivalent Vent Length ..................... 48  \nPolypropylene Vent Products ................ 50  \nTermination Requirements .................. 51  \nNon-Direct Venting ......................... 52  \nNon-Direct Venting in an Unconfined Space .... 52  \nNon-Direct Venting in a Confined Space ....... 52  \nNon-Direct Venting Terminations ............. 55  \nNon-Direct Venting Termination Clearances .... 57  \nDirect Venting ............................. 58  \nOption 1: Standard Vertical Direct Vent Termination ............................ 58  \nOption 2: Standard Horizontal Direct Vent Termination ............................ 60  \nOption 3: Variants of Standard Horizontal Direct Vent Termination ................... 60  \nOption 4: Alternate Horizontal Direct Vent Termination ............................ 61  \nOption 5: Variants of Alternate Horizontal Direct Vent Termination ................... 61  \nOptional Termination Angles for Alt. Horizontal and Variant of Alt. Horizontal Direct-Vent Terminations (Options 4 and 5) ... 62  \nOption 6 & 7: Vertical and Horizontal Concentric Vent Termination (RXGY-E02A and RXGY-E03A) ........................... 63  \nOption 8: Sidewall Vent Kit for Direct Vent Termination (RXGY-G02) ................. 64  \nDirect Venting Termination Clearances ........ 65  \nMultiventing of Direct Vent Furnaces .......... 66  \n8 CONDENSATE DRAIN AND DRAIN NEUTRALIZER .......................... 67  \n9 GAS SUPPLY AND PIPING  \nGas Supply ................................ 69  \nGas Piping ................................ 70  \nGas Pressure .............................. 73  \nGas Valve ................................. 73  \n10 LP CONVERSION .......................... 74  \n11 Setting the Gas Pressure.................... 75  \n12 ELECTRICAL WIRING","cbCaijyh5krPZS8s","https://ap.wps.com/l/cbCaijyh5krPZS8s","pdf",33726154,124,"English","# Table of Contents\n## General Information\n## Safety Information\n## Location Requirements\n## Field Conversion\n## Ducting\n## Venting\n## Condensate Drain and Drain Neutralizer\n## Gas Supply and Piping\n## LP Conversion\n## Electrical Wiring\n## Accessories\n## Twinining (Not Permitted)\n## High Altitude Installations\n## Startup\n## Sequence of Operations\n## Integrated Furnace Control\n## Humidification/Dehumidification\n## Dipswitches\n## Model Data Card\n## Dual 7-Segment Display\n## Pushbutton\n## Sensors and Auxiliary Inputs\n## Thermostat Wiring Diagrams\n## Fuse\n## Timing Diagram\n## Adjusting and Checking Input Rate\n## Airflow\n## Maintenance\n## Replacement Parts\n## Diagnostics and Troubleshooting","[{\"question\":\"What safety devices are recommended for installation of the 96V series furnaces?\",\"answer\":\"U.L. and/or C.S.A. recognized fuel gas and CO (carbon monoxide) detectors are recommended, and installation should follow manufacturer recommendations and applicable local laws and regulations.\"},{\"question\":\"What topics are covered under field conversion?\",\"answer\":\"Field conversion includes general conversion instructions and tips, lists of materials for parts bags and conversion kits, conversion table contents, and multiple installation orientations (e.g., upflow, downflow, and horizontal configurations).\"},{\"question\":\"Which diagnostics areas are included for troubleshooting?\",\"answer\":\"Diagnostics and troubleshooting include standard operation codes, fault codes with descriptions and solutions, lockout procedures, guidance for replacing the furnace control, and diagnosing blower motor issues.\"}]","96V Series - Installation Instructions - Two-Stage Communicating Gas Furnaces | PDF",1792714785,312]