[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662101-105":59,"doc-detail-662101-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","9200-513-side-mount-work-top-refrigerator-series-operator-manual","9200-513 Side Mount Work Top Refrigerator Series - Operator Manual","","Operator manual instructions for the Randell 9200-513 side mount work top refrigerator series, covering safety requirements, installation and service warnings, and the importance of retaining the manual for future reference. It includes contact information, part number and revision details, model specifications, and guidance for proper placement, ventilation, clearances, electrical supply, and startup checks. The manual also details how to locate and record serial numbers and emphasizes warranty conditions tied to correct installation and voltage compliance.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/9200-513-side-mount-work-top-refrigerator-series-operator-manual/662101/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/9200-513-side-mount-work-top-refrigerator-series-operator-manual/662101.png","ImageObject",300,407,{"name":92,"@type":93},"Jiven","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety warnings must be followed before installation or servicing?","Question",{"text":112,"@type":113},"Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. The manual requires reading and following the installation, operating, and maintenance instructions, and keeping the unit’s dedicated electrical line requirements.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How do I locate the serial number for this unit?",{"text":117,"@type":113},"The serial number is located in the cabinet left side under the drawer track. The manual provides an example and instructs users to record the information in the manual for future replacement parts orders or warranty service requests.",{"name":119,"@type":110,"acceptedAnswer":120},"What electrical and voltage conditions are required to avoid warranty issues?",{"text":121,"@type":113},"The unit must be on its own dedicated line, and condensing units are designed to operate within plus or minus 10% of the voltage indicated on the unit data tag. The manual also instructs checking the voltage reading at the compressor motor electrical connections while the unit is operating.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662101,1793199686,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},1099513958607,"https://ap-avatar.wpscdn.com/avatar/100002390cf8733938c?x-image-process=image/resize,m_fixed,w_180,h_180&k=1778829742770036399","| | |\n| --- | --- |\n| OPERATOR MANUAL\u003Cbr>IMPORTANT INFORMATION, KEEP FOR OPERATOR\u003Cbr>\u003Cbr>88-994-7636, fax 888-864-7636 [randell.com](randell.com) |  |\n\nTHIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.  \nFOR YOUR SAFETY Do not store or use gasoline or other flammable vaporsand liquids in the vicinity of this or any other appliance.  \nWARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.  \nNOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Randell suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once.  \nManufacture Service/Questions 888-994-7636.  \nPART NUMBER PP MNL1711, REV. C (12/25)  \nThis manual provides information for:  \n9200-513 SIDE MOUNT  \nWORK TOP REFRIGERATOR SERIES  \nRETAIN THIS MANUAL FOR FUTURE REFERENCE  \nNOTICE: Due to a continuous program of product improvement, Randell reserves the right to make changes in design and specifications without prior notice.  \nNOTICE: Please read the entire manual carefully before installation. If certain recommended procedures are not followed, warranty claims will be denied.  \nMODELNUMBER    \nSERIAL NUMBER   INSTALLATION DATE    \nThe serial number is located in the cabinet left side under the drawer track. An example is shown here.  \nEQUIPMENT DESCRIPTION  \n\n| MODEL | LENGTH | DEPTH | HEIGHT | NO. OF DOORS | STORAGE\u003Cbr>(CUBIC FEET) | SHELVES\u003Cbr>(CUBIC FEET) | HP | VOLT | AMPS | NEMA | SHIP WT\u003Cbr>(LBS) |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 9215-513 | 48” | 33” | 36” | (2) 18” | 11.58 | 9.5 | 1/4 | 115/60/1 | 6.5 | 5-15P | 325 |\n| 9205-513 | 60” | 33” | 36” | (2) 24” | 16.21 | 13.5 | 1/4 | 115/60/1 | 6.5 | 5-15P | 370 |\n| 9235-513 | 72” | 33” | 36” | (2) 27” | 20.01 | 20 | 1/4 | 115/60/1 | 6.5 | 5-15P | 370 |\n| 9225-513 | 84” | 33” | 36” | (2) 24”,(1) 18” | 23.16 | 20 | 1/4 | 115/60/1 | 6.5 | 5-15P | 420 |\n\nINSTALLATION  \nWARNING: FAILURE TO FOLLOW INSTALLATION GUIDELINES AND RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.  \nWARNING: IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE. CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING VOLTAGE LIMITS WILL VOID THE  \nWARRANTY.  \nWARNING: IT IS IMPORTANT THAT A VOLTAGE READING BE MADE AT THE COMPRESSOR MOTOR ELECTRICAL CONNECTIONS, WHILE THE UNIT IS IN OPERATION TO VERIFY THE CORRECT VOLTAGE REQUIRED BY THE COMPRESSOR IS BEING SUPPLIED. LOW OR HIGH VOLTAGE CAN DETRIMENTALLY AFFECT OPERATION AND THEREBY VOID ITS WARRANTY.  \nWARNING: ALL SELF-CONTAINED MODELS ARE SHIPPED FROM THE FACTORY WITH THE SERVICE VALES OPEN AND READY FOR OPERATION.  \nWARNING: ALL MOTORS ARE OILED AND SEALED.  \nInformation contained in this document is known to be current and accurate at the time of printing/creation. Reference our product line website for the most updated product information and specifications. © 2026 Electrolux Professional, Inc. All Rights Reserved.  \nThe following conditions should be considered when selecting a location foryour unit:  \n1. Floor and Countertop Load: The area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined weights of the unit plus the maximum product load weight.  \n2. Clearance: Clearance must be a combined total of at least 1” on back of unit. Do not place any object that can block the ventilation exhaust from the machin","cbCaiogoDG5fBSyw","https://ap.wps.com/l/cbCaiogoDG5fBSyw","pdf",1643278,"English","# Important Information\n## Safety and Warnings\n## Equipment Description\n## Installation\n## Checklist\n## Electrical Supply","[{\"question\":\"What safety warnings must be followed before installation or servicing?\",\"answer\":\"Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. The manual requires reading and following the installation, operating, and maintenance instructions, and keeping the unit’s dedicated electrical line requirements.\"},{\"question\":\"How do I locate the serial number for this unit?\",\"answer\":\"The serial number is located in the cabinet left side under the drawer track. The manual provides an example and instructs users to record the information in the manual for future replacement parts orders or warranty service requests.\"},{\"question\":\"What electrical and voltage conditions are required to avoid warranty issues?\",\"answer\":\"The unit must be on its own dedicated line, and condensing units are designed to operate within plus or minus 10% of the voltage indicated on the unit data tag. The manual also instructs checking the voltage reading at the compressor motor electrical connections while the unit is operating.\"}]","9200-513 Side Mount Work Top Refrigerator Series - Operator Manual | PDF",23]