[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-505378-105":59,"doc-detail-505378-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","608-recordkeeping-and-reporting-guide-march-8-2017","608 Recordkeeping and Reporting Guide - March 8, 2017","","Guide outlining recordkeeping and reporting requirements for the Section 608 Refrigerant Management Program. Applies to refrigerant reclaimers, wholesalers, technician certification programs, small appliance disposal facilities, and technicians, owners/operators, manufacturers of small MVAC refrigerant cans, and recovery/recycling equipment testing organizations. Explains exempt substitute refrigerants as of March 2017, summarizes recordkeeping duties by appliance charge size, and details onsite retention, electronic availability, and reporting submission approaches to EPA.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/608-recordkeeping-and-reporting-guide-march-8-2017/505378/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/608-recordkeeping-and-reporting-guide-march-8-2017/505378.png","ImageObject",300,407,{"name":92,"@type":93},"kopisore","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-23","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What entities are covered by the Section 608 Refrigerant Management Program recordkeeping and reporting requirements?","Question",{"text":113,"@type":114},"The guide applies to refrigerant reclaimers, refrigerant wholesalers, technician certification programs, small appliance disposal facilities, technicians, owners/operators of appliances with charge sizes over 50 pounds, manufacturers of small cans of MVAC refrigerant, and refrigerant recovery/recycling equipment testing organizations.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How long must required records be kept and where must they be available?",{"text":118,"@type":114},"Records maintained under the Section 608 program must be available onsite at the respondent’s place of business for at least three years (or longer if specified). Records may be kept in hard copy or electronically, including off-site electronic records that remain accessible through the internet or other means at the specified site.",{"name":120,"@type":111,"acceptedAnswer":121},"Which substitute refrigerants are exempt as of March 2017 according to the guide?",{"text":122,"@type":114},"The guide lists exempt substitutes including carbon dioxide, nitrogen, water, ammonia (in specified uses), chlorine (industrial process refrigeration), hydrocarbons (industrial process refrigeration), ethane (R-170) in very low temperature equipment and non-mechanical heat transfer equipment, propane (R-290) in listed retail and household/freezer and related applications, isobutane (R-600a) in listed stand-alone and vending/household uses, and R-441A in listed applications.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},505378,1791215295,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":36,"preview_page_count":19,"preview_urls":146},962090880963,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Recordkeeping and Reporting for the 608 Refrigerant Management Program  \nMarch 8, 2017  \nU.S. Environmental Protection Agency Stratospheric Protection Division Office of Atmospheric Programs 1200 Pennsylvania Avenue, NW Washington, DC 20460  \nI. Introduction  \nThe following guide describes the recordkeeping and reporting requirements of the Section 608 Refrigerant Management Program. These requirements are applicable to refrigerant reclaimers, refrigerant wholesalers, technician certification programs, small appliance disposal facilities, technicians, owners/operators of appliances with charge sizes of more than 50 pounds, manufacturers of small cans of MVAC refrigerant, and refrigerant recovery/recycling equipment testing organizations.  \nThis document is intended to assist entities with their recordkeeping and reporting obligations. This guidance does not supersede the Code of Federal Regulations (CFR) . Please consult the CFR for the complete list of requirements.  \nThis guidance and the requirements in 40 CFR part 82, subpart F do not apply to certain refrigerants. As of March 2017, the list of exempt substitute refrigerants includes:  \n􀂄 Carbon dioxide in any application;  \n􀂄 Nitrogen in any application;  \n􀂄 Water in any application;  \n􀂄 Ammonia in commercial or industrial process refrigeration or in absorption units;  \n􀂄 Chlorine in industrial process refrigeration (processing of chlorine and chlorine compounds);  \n􀂄 Hydrocarbons in industrial process refrigeration (processing of hydrocarbons);  \n􀂄 Ethane (R-170) in very low temperature refrigeration equipment and equipment for non-mechanical heat transfer;  \n􀂄 Propane (R-290) in retail food refrigerators and freezers (stand-alone units only); household refrigerators, freezers, and combination refrigerators and freezers; self-contained room air conditioners for residential and light commercial air-conditioning and heat pumps; vending machines; and self-contained commercial ice machines, very low temperature refrigeration equipment, and water coolers;  \n􀂄 Isobutane (R-600a) in retail food refrigerators and freezers (stand-alone units only); household refrigerators, freezers, and combination refrigerators and freezers; and vending machines; and  \n􀂄 R-441A in retail food refrigerators and freezers (stand-alone units only); household refrigerators, freezers, and combination refrigerators and freezers; self-contained room air conditioners for residential and light commercial air-conditioning; heat pumps; and vending machines.  \nThe most up-to-date list of substitutes that are exempt from the Clean Air Act Section 608 program can be found at [https://go.usa.gov/xXaZU](https://go.usa.gov/xXaZU).  \nII. Summary of Recordkeeping by Appliance Charge Size  \n\n|  | 5 pounds and Under | Between 5 and 50 Pounds | 50 pounds and Over |\n| --- | --- | --- | --- |\n| Technician | None | Yes-Only for disposal of the appliance | Yes-Must provide records to the owner/operator that are generated by the technician |\n| Owner/Operator | None | None | Yes |\n| Appliance\u003Cbr>Disposal Facility | Yes | None | None |\n\nIII. Recordkeeping and Reporting Requirements by Entity  \nAll records that must be maintained under the Section 608 program must be available onsite at the respondents' place of business for a minimum of three years (or longer if specified) . Records may be kept in hard copy or electronically. Electronic records may be off-site but must still accessible through the internet or other means at the specified site (e.g., site of the appliance or site of the disposal facility) .  \nWhen reporting is required, EPA encourages entities to submit reports electronically to [608reports@epa.gov](608reports@epa.gov. Entities may also submit)[. Entities may also submit](608reports@epa.gov. Entities may also submit) reports by mail to: Section 608 Program Manager; Stratospheric Protection Division; Mail Code: 6205T; U.S. Environmental Protection Agency; 1200 Pennsylvania Avenue, NW; Washington, DC 20460.  \n1","cbCainuW7D705RlT","https://ap.wps.com/l/cbCainuW7D705RlT","pdf",292982,16,"English","# I. Introduction\n# II. Summary of Recordkeeping by Appliance Charge Size\n# III. Recordkeeping and Reporting Requirements by Entity\n## 1) Refrigerant Reclaimers","[{\"question\":\"What entities are covered by the Section 608 Refrigerant Management Program recordkeeping and reporting requirements?\",\"answer\":\"The guide applies to refrigerant reclaimers, refrigerant wholesalers, technician certification programs, small appliance disposal facilities, technicians, owners/operators of appliances with charge sizes over 50 pounds, manufacturers of small cans of MVAC refrigerant, and refrigerant recovery/recycling equipment testing organizations.\"},{\"question\":\"How long must required records be kept and where must they be available?\",\"answer\":\"Records maintained under the Section 608 program must be available onsite at the respondent’s place of business for at least three years (or longer if specified). Records may be kept in hard copy or electronically, including off-site electronic records that remain accessible through the internet or other means at the specified site.\"},{\"question\":\"Which substitute refrigerants are exempt as of March 2017 according to the guide?\",\"answer\":\"The guide lists exempt substitutes including carbon dioxide, nitrogen, water, ammonia (in specified uses), chlorine (industrial process refrigeration), hydrocarbons (industrial process refrigeration), ethane (R-170) in very low temperature equipment and non-mechanical heat transfer equipment, propane (R-290) in listed retail and household/freezer and related applications, isobutane (R-600a) in listed stand-alone and vending/household uses, and R-441A in listed applications.\"}]","608 Recordkeeping and Reporting Guide - March 8, 2017 | PDF",1791146148,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/775fefccc5ebf834e02d4aef840ecd5d.webp",983,1272,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3015e72ed4c85a54b3349c36da7d0ea2.webp",982,1270,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3c3718e992330baf8c43b80df0136278.webp",981,1269,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e5fc7e1d72be910a42a37e30e1ff0bb9.webp",980,1268]