[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-565640-105":59,"doc-detail-565640-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","6-series-multiparameter-water-quality-sondes-user-manual-technical-support-and-warranty-information","6-Series Multiparameter Water Quality Sondes - User Manual - Technical Support and Warranty Information","","User Manual for YSI 6-Series multiparameter water quality sondes, covering instrument setup, connection, preparation for use, calibration readiness, measurement workflows, and data upload and analysis using EcoWatch for Windows. Includes a sonde menu overview, care/maintenance/storage guidance, principles of operation for key parameters, and dedicated sections on 650 MDS data logging, communication interfaces, firmware upgrading, and troubleshooting. Provides compliance notes, general safety considerations, and warranty/service information.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/6-series-multiparameter-water-quality-sondes-user-manual-technical-support-and-warranty-information/565640/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/6-series-multiparameter-water-quality-sondes-user-manual-technical-support-and-warranty-information/565640.png","ImageObject",300,407,{"name":92,"@type":93},"Kyle","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-14","2026-10-13",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does the manual cover for operating the YSI 6-Series sondes?","Question",{"text":112,"@type":113},"It covers getting started, connecting the sonde, preparing it for use, sonde software setup, getting ready to calibrate, taking readings, and uploading/analyzing data with EcoWatch for Windows.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Where are warranty and service details provided?",{"text":117,"@type":113},"Warranty and service information is included in Section 9, including limitations of warranty, authorized service centers, cleaning and packing instructions, and the product return form.",{"name":119,"@type":110,"acceptedAnswer":120},"What compatibility and safety notes are included for using the sondes in a CE country?",{"text":121,"@type":113},"The manual includes compliance guidance about possible electromagnetic compatibility (EMC) performance issues under certain radio frequency conditions, and it points users to the Declaration of Conformity and EMC performance appendix for details.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},565640,1792021427,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","6-Series  \nMultiparameter Water Quality Sondes  \nUser Manual  \n6-Series:  \n6600 V2  \n6600EDS V2 6920 V2  \n6820 V2 600 OMS V2  \n600XL 600XLM  \n600LS 600R 600QS  \nTECHNICAL SUPPORT AND WARRANTY INFORMATION  \n\n| Contact information for technical support and warranty information on YSI’s Environmental Monitoring Systems products can be found in Section 9, Warranty and Service Information.\u003Cbr>COMPLIANCE |\n| --- |\n| When using the YSI 6-Series sondes in a European Community (CE) country, please be aware that electromagnetic compatibility (EMC) performance issues may occur under certain conditions, such as when the sonde is exposed to certain radio frequency fields.\u003Cbr>If you are concerned with these issues, consult the Declaration of Conformity that was enclosed with your instrument. Specific conditions where temporary sensor problems may occur are listed in this document.\u003Cbr>The Declaration of Conformity for your instrument can be found in Appendix H, EMC Performance. A similar document for YSI Model 650 is located at the end of Section 3, 650 MDS.\u003Cbr>SPECIFICATIONS |\n| For general specifications for all YSI Environmental Monitoring Systems products included in this manual, please see Appendix O, Specifications.\u003Cbr>GENERAL SAFETY CONSIDERATIONS |\n| For Health and Safety issues concerning the use of the calibration solutions with the sondes, please see Appendix A, Health and Safety.\u003Cbr>NOTICE |\n\nInformation contained in this manual is subject to change without notice. Effort has been made to make the information contained in this manual complete, accurate, and current. YSI shall not beheld responsible for errors or omissions in this operations manual.  \nWARNING:  \nWhen caring for your sonde, remember that the sonde is sealed at the factory, and there is never a need to gain access to the interior circuitry of the sonde. In fact, if you attempt to disassemble the sonde, you would void the manufacturer's warranty.  \nTABLE OF CONTENTS  \nSECTION 1 INTRODUCTION  \n1.1 ABOUT YSI 1-1  \n1.2 HOW TO USE THIS MANUAL 1-1  \n1.3 UNPACKING AND INSPECTION 1.2  \nSECTION 2 SONDES  \n2.1 GETTING STARTED 2-1  \n2.2 CONNECTING YOUR SONDE 2-2  \n2.3 PREPARING THE SONDE FOR USE 2-5  \n2.4 ECOWATCH FOR WINDOWS – GETTING STARTED 2-24  \n2.5 SONDE SOFTWARE SETUP 2-25  \n2.6 GETTING READY TO CALIBRATE 2-34  \n2.7 TAKING READINGS 2-49  \n2.8 USING ECOWATCH TO UPLOAD AND ANALYZE DATA 2-54  \n2.9 SONDE MENU 2-68  \n2.10 CARE, MAINTENANCE, AND STORAGE 2-111  \nSECTION 3 650 MDS DATA LOGGER  \n3.1 INTRODUCTION 3-1  \n3.2 GETTING STARTED 3-1  \n3.3 SETTING UP THE 650 3-18  \n3.4 SONDE MENU INTERFACE 3-21  \n3.5 LOGGING DATA WITH THE 650 3-27  \n3.6 MANAGING 650 FILES 3-46  \n3.7 UPLOADING DATA FROM SONDES 3-51  \n3.8 USING GPS WITH 650 3-51  \n3.9 USING THE 650 BAROMETER 3-53  \n3.10 UPGRADING 650 SOFTWARE 3-55  \n3.11 TROUBLESHOOTING 3-56  \n3.12 FERRITE BEAD INSTALLATION 3-57  \n3.13 SAFETY CONSIDERATIONS 3-58  \n3.14 650 MDS SPECIFICATIONS 3-61  \nSECTION 4 ECOWATCH FOR WINDOWS  \n4.1 INTRODUCTION 4-1  \n4.2 DATA ACQUISITION AND ANALYSIS 4-7  \n4.3 ECOWATCH MENU 4-12  \nSECTION 5 PRINCIPLES OF OPERATION  \n5.1 CONDUCTIVITY 5-1  \n5.2 SALINITY 5-2  \n5.3 TOTAL DISSOLVED SOLIDS (TDS) 5-2  \n5.4 OXIDATION REDUCTION POTENTIAL (ORP) 5-3  \n5.5 pH 5-4  \n5.6 DEPTH AND LEVEL 5-6  \n5.7 TEMPERATURE 5-7  \n5.8 DISSOLVED OXYGEN RAPID PULSE 5-7  \n5.9 DISSOLVED OXYGEN ROX OPTICAL 5-10  \n5.10 NITRATE 5-12  \n5.11 AMMONIUM AND AMMONIA 5-14  \n5.12 CHLORIDE 5-16  \n5.13 TURBIDITY 5-17  \n5.14 CHLOROPHYLL 5-21  \n5.15 RHODAMINE 5-28  \n5.16 PHYCOCYANIN-CONTAINING BLUE-GREEN ALGAE 5-31  \n5.17 PHYCOERYTHRIN-CONTAINING BLUE-GREEN ALGAE 5-37  \n5.18 FLOW 5-42  \nSECTION 6 TROUBLESHOOTING  \n6.1 CALIBRATION ERRORS 6-1  \n6.2 SONDE COMMUNICATION PROBLEMS 6-2  \n6.3 SENSOR PERFORMANCE PROBLEMS 6-3  \nSECTION 7 COMMUNICATION  \n7.1 OVERVIEW 7-1  \n7.2 HARDWARE INTERFACE 7-1  \n7.3 RS-232 INTERFACE 7-2  \n7.4 SDI-12 INTERFACE 7.2  \nSECTION 8 UPGRADING SONDE FIRMWARE 8.1  \nSECTION 9 WARRANTY AND SERVICE INFORMATION  \n9.1 LIMITATIONS OF WARRA","cbCaitrHWjBq0yJS","https://ap.wps.com/l/cbCaitrHWjBq0yJS","pdf",8858786,379,"English","# SECTION 1 INTRODUCTION\n## 1.1 ABOUT YSI\n## 1.2 HOW TO USE THIS MANUAL\n## 1.3 UNPACKING AND INSPECTION\n# SECTION 2 SONDES\n## 2.1 GETTING STARTED\n## 2.2 CONNECTING YOUR SONDE\n## 2.3 PREPARING THE SONDE FOR USE\n## 2.4 ECOWATCH FOR WINDOWS – GETTING STARTED\n## 2.5 SONDE SOFTWARE SETUP\n## 2.6 GETTING READY TO CALIBRATE\n## 2.7 TAKING READINGS\n## 2.8 USING ECOWATCH TO UPLOAD AND ANALYZE DATA\n## 2.9 SONDE MENU\n## 2.10 CARE, MAINTENANCE, AND STORAGE\n# SECTION 3 650 MDS DATA LOGGER\n## 3.1 INTRODUCTION\n## 3.2 GETTING STARTED\n## 3.3 SETTING UP THE 650\n## 3.4 SONDE MENU INTERFACE\n## 3.5 LOGGING DATA WITH THE 650\n## 3.6 MANAGING 650 FILES\n## 3.7 UPLOADING DATA FROM SONDES\n## 3.8 USING GPS WITH 650\n## 3.9 USING THE 650 BAROMETER\n## 3.10 UPGRADING 650 SOFTWARE\n## 3.11 TROUBLESHOOTING\n## 3.12 FERRITE BEAD INSTALLATION\n## 3.13 SAFETY CONSIDERATIONS\n## 3.14 650 MDS SPECIFICATIONS\n# SECTION 4 ECOWATCH FOR WINDOWS\n## 4.1 INTRODUCTION\n## 4.2 DATA ACQUISITION AND ANALYSIS\n## 4.3 ECOWATCH MENU","[{\"question\":\"What does the manual cover for operating the YSI 6-Series sondes?\",\"answer\":\"It covers getting started, connecting the sonde, preparing it for use, sonde software setup, getting ready to calibrate, taking readings, and uploading/analyzing data with EcoWatch for Windows.\"},{\"question\":\"Where are warranty and service details provided?\",\"answer\":\"Warranty and service information is included in Section 9, including limitations of warranty, authorized service centers, cleaning and packing instructions, and the product return form.\"},{\"question\":\"What compatibility and safety notes are included for using the sondes in a CE country?\",\"answer\":\"The manual includes compliance guidance about possible electromagnetic compatibility (EMC) performance issues under certain radio frequency conditions, and it points users to the Declaration of Conformity and EMC performance appendix for details.\"}]","6-Series Multiparameter Water Quality Sondes - User Manual - Technical Support and Warranty Information | PDF",1791856796,955]