[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648475-105":59,"doc-detail-648475-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","5868-rega-drive-site-evaluation-septic-design-package-2025","5868 Rega Drive - Site Evaluation & Septic Design Package - 2025","","Onsite septic system site evaluation and design package for a 2-bedroom stone and pipe leach field at 5868 Rega Drive, Toledo, OH 43623 (Lucas County; Sylvania Township), prepared for Jeffrey Carter/WPCLF by Geophyta Inc. The package compiles system layout maps, soil report and soil profile test data, calculation sheets, CAD layouts, elevation drawings, and bill of materials. It includes homeowner/installer disclaimers detailing responsibilities for design accuracy, regulatory drawing compliance, and installer “as-built” record requirements under Ohio rules.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/5868-rega-drive-site-evaluation-septic-design-package-2025/648475/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/5868-rega-drive-site-evaluation-septic-design-package-2025/648475.png","ImageObject",300,407,{"name":92,"@type":93},"Sarah ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-08","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What septic system type is designed in this package?","Question",{"text":112,"@type":113},"A 2-bedroom stone and pipe leach field system is specified for the property at 5868 Rega Drive, Toledo, OH 43623.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Who prepared the site evaluation and design drawings?",{"text":117,"@type":113},"Geophyta Inc. prepared the package, with Nathan Wright (soil scientist), Caleb Layne (soil scientist apprentice), and Seth V. Layne (septic designer) listed.",{"name":119,"@type":110,"acceptedAnswer":120},"What responsibilities are assigned to the installer regarding “as-built” records?",{"text":121,"@type":113},"The registered installer is responsible for creating an “as-built” record and for measuring and recording distal pressure head and float switch settings as baseline measures for future operation and maintenance.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648475,1793048418,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":56,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":4},962085320529,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","ONSITE SEPTIC SYSTEM SITE EVALUATION & DESIGN  \nCLIENT: PROPERTY:  \nJEFFREY CARTER | WPCLF  \n5868 REGA DRIVE, TOLEDO, OH 43623  \n419.392.0461  \n5868 REGA DRIVE, TOLEDO, OH 43623  \nTOWNSHIP: COUNTY:  \nSYLVANIA LUCAS  \nSYSTEM TYPE:  \n2 BEDROOM STONE AND PIPE LEACH FIELD  \n1 DISCLAIMER  \n2 LAYOUT MAP  \n3 SOIL REPORT  \n4 CALCULATION SHEETS  \n5 3D CAD LAYOUT  \n6 TOP CAD LAYOUT  \n7 ELEVATION CAD LAYOUT  \n8 BILL OF MATERIALS  \n9 COMPONENT SPEC SHEETS  \nBY:  \nNATHAN WRIGHT (SOIL SCIENTIST) CALEB LAYNE (SOIL SCIENTIST APPRENTICE)  \nSETH V . LAYNE (SEPTIC DESIGNER)  \nGEOPHYTA INC .  \n2685 COUNTY ROAD 254, VICKERY, OH 43464 419.547.8538 OCTOBER 22ND, 2025  \nTo The Homeowner:  \nA septic system is designed based on all the information you provide and Geophyta Inc collects at the site. It must be accurate. This information includes local soil limits and topography, plus existing and future locations of your home, number of bedrooms, outbuildings, driveways, drinking water wells, ponds, septic systems, and property lines. Geophyta Inc. relies on this information to construct detailed design drawings that must meet local health department regulations before installation.  \nAny design changes required by the local health department to meet existing regulations are the responsibility of Geophyta Inc.  \nAny information changes made by you after the initial site inspection are your responsibility and will result in additional charges to you above the original quote for services. These charges may include additional site inspection work, system redesign, and resubmitted drawings.  \nTo The Installer:  \nThe registered installer of this septic system design is responsible for preparing an “asbuilt” record, as stated in the Ohio Administrative Code Chapter 3701-29-09, Par. F (p.32) of the “Sewage Treatment System Rules,” Ohio Department of Health, January 1, 2015. Additionally, the installer is responsible for measuring and recording distal pressure head and float switch settings as baseline measures for future operation and maintenance of any pressure distribution system (3701-29-15, Appendix B, Par. VI(p.93) of above referenced rules.  \nIf the installer requests “as-built” record creation from Geophyta Inc., additional charges will be billed to the installer by Geophyta Inc. and must be arranged prior to installation.  \nGeophyta Inc. must assume that any registered installer has the knowledge, equipment, ability, and experience to properly layout, install, and create as-built drawings for any septic system design approved by a local board of health. This includes the ability to read detailed design prints with an associated bill of materials. For this reason, any Geophyta Inc project supervision prior to or during installation will be billed to the installer.  \nAny product substitution made by the installer that is not specifically permitted in the design prints may result in Health Dept. disapproval and will result in additional redesign costs billed to the installer.  \nHSTS Replacement Layout - 5868 Rega Drive 10 .22 .25  \n24  \n22  \n21  \n2019  \n18  \nExisting Tank *See NOTES*  \n8.92 4TOP  \nSite and Soil Evaluation for Sewage Treatment and Dispersal  \nCounty:  Lucas  Township / Sec.:  Sylvania  Property Address:  5868 Rega Dr  OR Location:  Toledo, OH 43623  Applicant Name:  Jeffrey Carter   \nAddress:  5868 Rega Dr  Toledo, OH 43623   \nLand Use / Vegetation:  Residential Turf  Control \\#  25- LUC- 12A - 283  Landform:  Glacial Lake Plain   \nPosition on Landform:  Local Depression   \nPercent Slope:  0-1   \nShape of Slope:  Linear-Linear   \nApproximate Soil Type:  Fill / Tedrow LS   \nCertification \\#:  19395   \nPhone \\#:  419-392-0461  Lot \\#:    \nTest Hole \\#:  A   \nLatitude/Longitude:  83°38'46.751\"W 41°43'19.632\"N  Method:   Pit   Auger  X  Probe; 1 1/4\" dia.  \nDate:  9-Sep-25   \nEvaluator:  Nathan Wright   Geophyta, Inc.   \n2685 C.R. 254   \nVickery, OH 43464  Phone\\#: 419-547-8538  \nSignature:  \n| Soil Profile |  | Estimating Soil Saturation |  | ","cbCairXHiAVq9g3x","https://ap.wps.com/l/cbCairXHiAVq9g3x","pdf",5174676,"English","# Onsite Septic System Site Evaluation & Design\n## Client and Project Information\n## Disclaimers and Responsibilities\n## Layout Maps and CAD Drawings\n## Soil Report and Soil Profile\n## Design Calculations and Components","[{\"question\":\"What septic system type is designed in this package?\",\"answer\":\"A 2-bedroom stone and pipe leach field system is specified for the property at 5868 Rega Drive, Toledo, OH 43623.\"},{\"question\":\"Who prepared the site evaluation and design drawings?\",\"answer\":\"Geophyta Inc. prepared the package, with Nathan Wright (soil scientist), Caleb Layne (soil scientist apprentice), and Seth V. Layne (septic designer) listed.\"},{\"question\":\"What responsibilities are assigned to the installer regarding “as-built” records?\",\"answer\":\"The registered installer is responsible for creating an “as-built” record and for measuring and recording distal pressure head and float switch settings as baseline measures for future operation and maintenance.\"}]","5868 Rega Drive - Site Evaluation & Septic Design Package - 2025 | PDF",1792793673,48]