[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-559523-105":59,"doc-detail-559523-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","5520a-service-supplement-issue-8-dc-current-and-ac-current-specifications-updates","5520A Service Supplement - Issue 8 - DC Current and AC Current Specifications Updates","","5520A Service Supplement Issue 8 provides manual update instructions and detailed electrical specification changes required to maintain accuracy. It defines conditions for entering corrections based on stamped revision letters tied to indicated PCAs and specifies replacement pages for DC Current and AC Current (Sine Wave) specifications. The supplement includes expanded DC current range tables with uncertainty, resolution, compliance voltage, inductive load limits, noise, bandwidth, and duty-cycle notes, followed by AC sine-wave tables covering frequency ranges, absolute uncertainty, compliance voltage adders, distortion/noise limits, and inductive load.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/5520a-service-supplement-issue-8-dc-current-and-ac-current-specifications-updates/559523/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/5520a-service-supplement-issue-8-dc-current-and-ac-current-specifications-updates/559523.png","ImageObject",300,407,{"name":92,"@type":93},"River Wang","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What conditions require corrections to be entered into the manual?","Question",{"text":112,"@type":113},"Corrections must be entered if the revision letter stamped on the indicated PCA is equal to or higher than the revision given with each change, or if no revision letter is indicated at the beginning of the change.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which pages are replaced for the DC current specification changes?",{"text":117,"@type":113},"The supplement specifies replacing page 1-9 and 1-11 with updated DC Current Specifications (1-11).",{"name":119,"@type":110,"acceptedAnswer":120},"What does the supplement provide for AC current (sine wave) specifications?",{"text":121,"@type":113},"It provides replacement AC current (sine wave) specifications for page 1-14, including frequency-dependent absolute uncertainty, compliance voltage adder, maximum distortion and noise limits, and maximum inductive load values.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},559523,1792302200,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},1099514067438,"https://ap-avatar.wpscdn.com/avatar/100002539ee87300030?x-image-process=image/resize,m_fixed,w_180,h_180&k=1780474512215547542","Manual Supplement  \nManual Title: 5520A Service Supplement Issue: 8  \nPart Number: 802303 Issue Date: 4/14  \nPrint Date: April 1999 Page Count: 6  \nRevision/Date: 1, 12/02  \nThis supplement contains information necessary to ensure the accuracy of the above manual. Enter the corrections in the manual if either one of the following conditions exist:  \n1. The revision letter stamped on the indicated PCA is equal to or higher than that given with each change.  \n2. No revision letter is indicated at the beginning of the change.  \n© 2003-2014 Fluke Corporation. All rights reserved..  \n􀀬  \nChange \\#1  \nReplace page 1-9, 1-11. DC Current Specifications , with the following:  \n1-11. DC Current Specifications  \n\n| Range | Absolute Uncertainty, tcal 􀁲 5 􀁱 C\u003Cbr>􀁲 (ppm of output 􀀎 􀁐A) |  | Resolution | Max\u003Cbr>Compliance\u003Cbr>Voltage\u003Cbr>V | Max\u003Cbr>Inductive\u003Cbr>Load\u003Cbr>mH |\n| --- | --- | --- | --- | --- | --- |\n|  | 90 days | 1 year |  |  |  |\n| 0 to 329.999 mA | 120 􀀎 0.02 | 150 􀀎 0.02 | 1 nA | 10 | 400 |\n| 0 to 3.29999 mA | 80 􀀎 0.05 | 100 􀀎 0.05 | 0.01 􀁐A | 10 |  |\n| 0 to 32.9999 mA | 80 􀀎 0.25 | 100 􀀎 0.25 | 0.1 􀁐A | 7 |  |\n| 0 to 329.999 mA | 80 􀀎 2.5 | 100 􀀎 2.5 | 1 􀁐A | 7 |  |\n| 0 to 1.09999 A | 160 + 40 | 200 􀀎 40 | 10 􀁐A | 6 |  |\n| 1.1 to 2.99999 A | 300 + 40 | 380 􀀎 40 | 10 􀁐A | 6 |  |\n| 0 to 10.9999 A\u003Cbr>(20 A Range) | 380 􀀎 500 | 500 􀀎 500 | 100 􀁐A | 4 |  |\n| 11 to 20.5 A [1] | 800 􀀎 750 [2] | 1000 􀀎 750 [2] | 100 􀁐A | 4 |  |\n| [1] Duty Cycle: Currents \u003C 11 A may be provided continuously. For currents > 11 A, see Figure 1-4. The current maybe provided 60-T-I minutes any 60 minute period where T is the temperature in 􀁱 C (room temperature is about 23􀁱 C) and I is the output current in Amps. For example, 17 A, at 23 􀁱 C could be provided for 60-17-23 = 20 minutes each hour. When the 5520A is outputting currents between 5 and 11 amps for long periods, the internal selfheating reduces the duty cycle. Under those conditions, the allowable \"on\" time indicated by the formula and Figure 1-4 is achieved only after the 5520A is outputting currents \u003C 5A for the \"off\" period first.\u003Cbr>[2] Specifications apply within two minutes of selecting operate. |  |  |  |  |  |\n\n\n| Range | Noise |  |\n| --- | --- | --- |\n|  | Bandwidth\u003Cbr>0.1 Hz to 10 Hz\u003Cbr>p-p | Bandwidth\u003Cbr>10 Hz to 10 kHz\u003Cbr>rms |\n| 0 to 329.999 􀁐A | 2 nA | 20 nA |\n| 0 to 3.29999 mA | 20 nA | 200 nA |\n| 0 to 32.9999 mA | 200 nA | 2.0 􀁐A |\n| 0 to 329.999 mA | 2000 nA | 20 􀁐A |\n| 0 to 2.99999 A | 20 􀁐A | 1 mA |\n| 0 to 20.5 A | 200 􀁐A | 10 mA |\n\n5520A Service Manual Supplement  \nReplace page 1-14, 1-14. AC Current (Sine Wave) Specifications with the following:  \n1-14. AC Current (Sine Wave) Specifications  \n\n| LCOMP off |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| Range | Frequency | Absolute Uncertainty, tcal 􀁲 5 􀁱 C\u003Cbr>􀁲 (% of output 􀀎 􀁐A) |  | Compliance\u003Cbr>adder\u003Cbr>􀁲 (􀁐A/V) | Max\u003Cbr>Distortion &\u003Cbr>Noise 10 Hz\u003Cbr>to 100 kHz\u003Cbr>BW\u003Cbr>􀁲 (% output\u003Cbr>􀀎\u003Cbr>floor) | Max\u003Cbr>Inductive\u003Cbr>Load\u003Cbr>􀁐H |\n|  |  | 90 days | 1 year |  |  |  |\n| 29.00 􀁐A to\u003Cbr>329.99 􀁐A | 10 Hz to 20 Hz | 0.16 􀀎 0.1 | 0.2 􀀎 0.1 | 0.05 | 0.15 􀀎 0.5 􀁐A | 200 |\n|  | 20 Hz to 45 Hz | 0.12 􀀎 0.1 | 0.15 􀀎 0.1 | 0.05 | 0.1 􀀎 0.5 􀁐A |  |\n|  | 45 Hz to 1 kHz | 0.1 􀀎 0.1 | 0.125 􀀎 0.1 | 0.05 | 0.05 􀀎 0.5 􀁐A |  |\n|  | 1 kHz to 5 kHz | 0.25 􀀎 0.15 | 0.3 􀀎 0.15 | 1.5 | 0.5 􀀎 0.5 􀁐A |  |\n|  | 5 kHz to 10 kHz | 0.6 􀀎 0.2 | 0.8 􀀎 0.2 | 1.5 | 1.0 􀀎 0.5 􀁐A |  |\n|  | 10 kHz to 30 kHz | 1.2 􀀎 0.4 | 1.6 􀀎 0.4 | 10 | 1.2 􀀎 0.5 􀁐A |  |\n| 0.33 mA to\u003Cbr>3.2999 mA | 10 Hz to 20 Hz | 0.16 􀀎 0.15 | 0.2 􀀎 0.15 | 0.05 | 0.15 􀀎 1.5 􀁐A | 200 |\n|  | 20 Hz to 45 Hz | 0.1 􀀎 0.15 | 0.125 􀀎 0.15 | 0.05 | 0.06 􀀎 1.5 􀁐A |  |\n|  | 45 Hz to 1 kHz | 0.08 􀀎 0.15 | 0.1􀀎 0.15 | 0.05 | 0.02 􀀎 1.5 􀁐A |  |\n|  | 1 kHz to 5 kHz | 0.16 􀀎 0.2 | 0.2 􀀎 0.2 | 1.5 | 0.5 􀀎 1.5 􀁐A |  |\n|  | 5 kHz to 10 kHz | 0.4 􀀎 0.3 | 0.5 􀀎 0.3 | 1.5 | 1.0 􀀎 1.5 􀁐A |  |\n|  | 10 kHz to 30 kHz | 0.8 􀀎 0.6 | 1.0 􀀎 0.6 | 10 | 1.2 􀀎 0.5 􀁐A |  |\n| 3.3 mA to\u003Cbr>32.999 mA | 1","cbCaimhf3h7gAiB5","https://ap.wps.com/l/cbCaimhf3h7gAiB5","pdf",320562,"English","# Manual Supplement Information\n## Update Conditions and Revision Control\n## Change #1 - DC Current Specifications (1-11)\n## Noise and Bandwidth Specifications\n## Service Manual Supplement - AC Current (Sine Wave) Specifications (1-14)","[{\"question\":\"What conditions require corrections to be entered into the manual?\",\"answer\":\"Corrections must be entered if the revision letter stamped on the indicated PCA is equal to or higher than the revision given with each change, or if no revision letter is indicated at the beginning of the change.\"},{\"question\":\"Which pages are replaced for the DC current specification changes?\",\"answer\":\"The supplement specifies replacing page 1-9 and 1-11 with updated DC Current Specifications (1-11).\"},{\"question\":\"What does the supplement provide for AC current (sine wave) specifications?\",\"answer\":\"It provides replacement AC current (sine wave) specifications for page 1-14, including frequency-dependent absolute uncertainty, compliance voltage adder, maximum distortion and noise limits, and maximum inductive load values.\"}]","5520A Service Supplement - Issue 8 - DC Current and AC Current Specifications Updates | PDF",1791800707,18,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/24da161bc1af5b9d4cee1828759c2970.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1236113bbc1860ccc6cdddeb0ddfdabb.webp",982,1270,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3fc5469c750ec7216d768fe1f5353726.webp",981,1269,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e05bba297c1a034f1bc3c53f40babe1f.webp",980,1268]