[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646411-105":59,"doc-detail-646411-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","4000-sf-laundromat-utility-schedule-1-machine-installation-utility-requirements","4000-SF-Laundromat-Utility-Schedule-1 - Machine Installation Utility Requirements","","Utility schedule detailing required plumbing, electrical, gas, ventilation, and load parameters for 4000 SF laundromat equipment. Provides washer-extractor and dryer-related equipment lists with quantities, drain outlet sizing guidance per bulkhead, and estimated drain and gas line capacities. Includes gas inlet sizing assumptions, hot water and water line sizing notes, electrical voltage, circuit breaker, wire gauge, grounding and qualified electrician requirements, plus dynamic load and exhaust/vent outlet sizing with make-up air opening minimums.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/4000-sf-laundromat-utility-schedule-1-machine-installation-utility-requirements/646411/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/4000-sf-laundromat-utility-schedule-1-machine-installation-utility-requirements/646411.png","ImageObject",300,407,{"name":92,"@type":93},"fresh2021","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-24","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What information does the utility schedule provide for each laundromat machine?","Question",{"text":112,"@type":113},"It lists manufacturer/model, description, quantity, and key utility parameters such as drain outlet sizing, gas inlet sizing, electrical ratings, and dynamic load data.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How are estimated drain and gas line sizes determined?",{"text":117,"@type":113},"Estimated drain line and gas supply sizing are based on machine drain flow capacity and gas flow capacity assumptions, with final sizing requiring a professional consult due to local code, distance, plumbing configuration, and non-laundry fixture requirements.",{"name":119,"@type":110,"acceptedAnswer":120},"What installation and safety requirements are emphasized for the electrical and utility connections?",{"text":121,"@type":113},"Machines must be installed according to local codes, grounded in accordance with state and local codes, and connections must be made by a qualified electrician; electrical ratings may change, so the serial plate and installation manual should be referenced.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646411,1792879337,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":81},962093912154,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| LAUNDRY EQUIPMENT LIST   |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| 0   | MANUFACTURER   | MODEL   | DESCRIPTION   | QTY.   | FUTURE   |\n| 1   | 津   | SCT100VCOV   | WASHER-EXTRACTOR   | 2   |  |\n| 2   | 制   | SCT080VCOV   | WASHER-EXTRACTOR   | 4   |  |\n| 3   | 制   | SCT060VCOV   | WASHER-EXTRACTOR   | 8   |  |\n| 4   | 奉   | SCT040VCOV   | WASHER-EXTRACTOR   | 16   |  |\n| 5   | 制   | SCT020VCOV   | WASHER-EXTRACTOR   | 16   |  |\n| 6   | 制   | STT45N   | STACK TUMBLER   | 20   |  |\n| 7   |  | ST075N   | TUMBLER   | 6   |  |\n\n\n| DRAIN OUTLET SIZE   |  |  |\n| --- | --- | --- |\n| MODEL   | MACHNE DRAN OUTLET   | ESTMATED DRAN UNE  \u003Cbr>F0R EACH BULKHEAD   |\n| SCT100VcOV   | 3”   | TROUGH DRAINS   |\n| SCT080VCOV   | 3”   |  |\n| SCT060VCOV   | 3”   |  |\n| SCT040VCOV   | 3”   |  |\n| SCT020VCoV   | 3”   |  |\n\nIMPORTANT!:MACHINE MUST BE INSTALLED IN ACCORDANCE WITHLOCAL CODES AND ORDINANCES.  \nIMPORTANT!:THE ESTIMATED DRAIN LINE FOR EACH BULKHEAD ISBASED ON THE DRAIN FLOW CAPACITY OF EACH MACHINE,ANDONLY TAKES INTO ACCOUNT THE LAUNDRY EQUIPMENTREQUIREMENTS.WHEN CONDUCTING FINAL SIZING OF THEOUTGOING SEWER LINE,A PROFESSIONAL SHOULD BE CONSULTEDAS FIGURES MAY VARY BASED ON LOCAL CODE REGULATIONS,DISTANCE AND CONFIGURATION OF PLUMBING,AND OTHER SEWERREQUIREMENTS FROM NON-LAUNDRY FIXTURES.  \n\n| GAS INLET SIZE   |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| MODEL   | OPERATNG  \u003Cbr>PESRE   | GAS TYPE   | MAX MPUT  \u003Cbr>BTU /HOUR   | CONNECTION   \u003Cbr>SZE   | ESTIMATED GAS  \u003Cbr>SUPPLY LNE   |\n| STT45N   | 7“±1.5”   | NATURAL   | 190000   | 1/2”   | 4”   |\n| ST075N   | 7“±1.5”   | NATURAL   | 165000   | 1/2”   |  |\n| TOTAL   |  |  | 4790000   |  |  |\n\nNOTE:IT S_IMPORTANT THAT EQUAL PRESSURE BE MAINTAINED AT  \nALL TUMBLE DRYER GAS CONNECTIONS.THIS CAN BE DONE BYNSTALLING A1”(25.4mm)PIPE GAS LOOP TO MAINTAIN EQUALPRESSURE AT ALL GAS CONNECTIONS.  \nIMPORTANT!:THE ESTIMATED GAS SUPPLY LINE SIZE IS BASED ONA 0.5 PSI(0.04 bar)SUPPLY SYSTEM,AND 60'(18m)LENGTHOF PIPE,AND ONLY TAKES INTO ACCOUNT THE LAUNDRYEQUIPMENT REQUIREMENTS.WHEN CONDUCTING FINAL SIZING OFTHE INCOMING GAS LINE,A PROFESSIONAL SHOULD BE CONSULTEDAS FIGURES MAY VARY BASED ON SUPPLY SYSTEM SIZE,LOCALCODE REGULATIONS,DISTANCE AND CONFIGURATION OF PIPING,AND OTHER GAS REQUIREMENTS FROM NON-LAUNDRY FIXTURES.  \nNOTE:THE AVERAGE HOT WATER PER CYCLE FIGURE IS PER MACHINE,AND WAS CALCULATED BASED ON 60 PSI OPERATING PRESSURE.ALL HOT WATER USAGE FIGURES ARE ESTIMATED,ACTUAL CONSUMPTION FIGURES WILL VARY DEPENDING ON LOCAL WATER PRESSURES,EQUIPMENT CONDITION,NUMBER OF CYCLES,CYCLE TIMES SELECTED,LOAD SIZES AND THE TYPE OF MATERIALS PROCESSED.  \nIMPORTANT!:THE ESTIMATED WATER LINE SUPPLY SIZE IS BASED ON OPTIMUM WATER PRESSURE,AND ONLY TAKES INTO ACCOUNT THELAUNDRY EQUIPMENT REQUIREMENTS.WHEN CONDUCTING FINAL SIZING OF THE INCOMING WATER UINE,A PROFESSIONAL SHOULD BECONSULTED AS FIGURES MAY VARY BASED ON WATER PRESSURE AVAILABILITY,PLUMBING REGULATION REQUIREMENTS,DSTANCE ANDCONFIGURATION OF PIPING,AND OTHER WATER REQUIREMENTS FOR NON-LAUNDRY FIXTURES.  \n# 4000 SF LAUNDROMATSOLUTION\n\n| ELECTRICAL REQUIREMENTS   |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| MODEL   | VOLTAGE/CYCLE/PHASE   | FUL LOAD  \u003Cbr>AMP DRAW   | CIRCUIT  \u003Cbr>BREAKER   | WIRE SIZE  \u003Cbr>WG [mm]   |\n| SCT100VCOV    | 200-240/50-60/10   | 16A   | 20A   | 12[4]   |\n| SCT080VCOV    | 200-240/50-60/10   | 15A   | 20A   | [4]  \u003Cbr>12[   |\n| SCT060VCOV    | 200-240/50-60/10   | 11A   | 15A   | [2.5]  \u003Cbr>14[   |\n| SCTO40VCOV   |  |200-240/50-60/1g   | 7A   | 15A   | 14[2.5]   |\n| SCT020VCOV    | 200-240/50-60/10   | 4A   | 15A   | 14[2.5   |\n| STT45N   | 200-240/50-60/10   | 12A   | 15A   | 14[2.5]   |\n| ST075N   | 200-240/50-60/10   | 7A   | 15A   | 14[2.5]   |\n| TOTALS   |  | 638.0A   |  |  |\n\nNOTE:ELECTRICAL RATINGS ARE SUBJECT_TO CHANGE WITHOUT  \nNOTICE.REFER TO SERIAL PLATE FOR ELECTRICAL RATINGSINFORMATION SPECIFIC TO YOUR MACHINE.  \nNOTE:ELECTRIC HEATED STACK DRYER AND STACK 30 TUMBLEDRYER FULL LOAD","cbCaidrLOrEgSYeP","https://ap.wps.com/l/cbCaidrLOrEgSYeP","pdf",230089,"English","# Laundry equipment list\n# Drain outlet size\n# Gas inlet size\n# Electrical requirements\n# Dynamic load specifications\n# Exhaust/vent outlet size\n# Water inlet supply","[{\"question\":\"What information does the utility schedule provide for each laundromat machine?\",\"answer\":\"It lists manufacturer/model, description, quantity, and key utility parameters such as drain outlet sizing, gas inlet sizing, electrical ratings, and dynamic load data.\"},{\"question\":\"How are estimated drain and gas line sizes determined?\",\"answer\":\"Estimated drain line and gas supply sizing are based on machine drain flow capacity and gas flow capacity assumptions, with final sizing requiring a professional consult due to local code, distance, plumbing configuration, and non-laundry fixture requirements.\"},{\"question\":\"What installation and safety requirements are emphasized for the electrical and utility connections?\",\"answer\":\"Machines must be installed according to local codes, grounded in accordance with state and local codes, and connections must be made by a qualified electrician; electrical ratings may change, so the serial plate and installation manual should be referenced.\"}]","4000-SF-Laundromat-Utility-Schedule-1 - Machine Installation Utility Requirements | PDF",1792760502]