[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-562968-105":59,"doc-detail-562968-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","40-kv-probe-meter-model-im-5210-introduction-and-assembly-guide","40 kV Probe Meter - Model IM-5210 - Introduction and Assembly Guide","","Heathkit Model IM-5210 40 kV Probe Meter provides a self-contained probe for measuring extremely high DC voltages up to 40,000 volts. The guide explains safety precautions, including extreme danger of high voltages, correct use of the ground clip and probe switch, and limits to measurement range. It also covers the order of connections, rechecking solder joints, and detailed step-by-step wiring and assembly requirements. Specifications include voltage range, accuracy, and physical size and weight.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/40-kv-probe-meter-model-im-5210-introduction-and-assembly-guide/562968/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/40-kv-probe-meter-model-im-5210-introduction-and-assembly-guide/562968.png","ImageObject",300,407,{"name":92,"@type":93},"dawugda","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-14","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the maximum DC voltage that the Heathkit IM-5210 probe meter measures?","Question",{"text":112,"@type":113},"It measures extremely high DC voltages up to 40,000 volts, with a stated voltage range of 0–40 kV DC.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What safety precautions must be followed during use?",{"text":117,"@type":113},"Always ensure the ground clip is connected to the chassis and the probe switch is OFF when not making a measurement. Never measure DC voltages in excess of 40,000 volts.",{"name":119,"@type":110,"acceptedAnswer":120},"Why are careful solder connections emphasized in this guide?",{"text":121,"@type":113},"Many returned kits fail due to poor solder connections. Carefully inspect, reheat doubtful connections, and recheck wiring as described in the “Soldering” section of the Kit Builders Guide.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},562968,1792019206,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},3985747870947,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","40 KV PROBE METERR  \nMODEL IM-5210  \nThe Heathkit Model IM-521040 kV Probe Meter is aconvenient,self-contained probe that measures extremelyhigh DC voltages up to 40,000 volts.  \nThe on-off switch mounted on the handle protects the meterduring transportation and hookup.  \nAll rights raservwd  \n# INTRODUCTION\n\nCopyrighto 1975  \n595-1684-02  \nRefer to the \"Kit Builders Guide\"forinformation on tools,wiring,and soldering.  \nHeathkitMODELSERIES NO.IM-521003-44675  \nCheck each part against the followig list.  \nQTY.  \n.  DESCRIPTION  \n一  \nCAUTION:Do not unpack or handle the 800 MS resistoruntil you are instructed to do so in a step.Moisture fromyour fingers can change its resistance,and thus affect itsaccuracy.  \n1800 MΩ,1/2-watt,2%  2-331  \n1  \n1  \n1  \n7  \n# PARTS LIST\n\nCIRCUIT  \nPART  \nNo.  \nComponent No.  \nR1resistorSlide switch60-14SW1Rubber insulator73-211Handle topHandle bottom95-6061Handle tip26-32×5/16\"flat head 250-274screw2\\#6×5/8\"self-tapping 250-559screw2\\#2×1/4\"self-tapping250-582screw2\\#6 lockwasher254-12Spade lug259-321Alligator clip260-11Large black wire341-11Small black wire344-901Red wire344-92Meter407-196 M11Hex stud455-6371Probe tip477-121Switch label390-1194Heathkit nameplate390-1108Nut starter490-5Blue and white label391-34Parts Order Form597-260Kit Builders Guide597-308Instructions(Seefirst page forpart number.)Solder  \nTo order a replacement part:Use the Parts Order Formfurnished with this kit.For prices,refer to the separate\"Heath Parts Price List.\"  \nWARNING:  HIGH VOLTAGES ARE EXTREMELYDANGEROUS.NEVER MEASURE DC VOLTAGES INEXCESS OF 40,000 VOLTS.  \nThis probe is designed to permit high voltage measurementsto be made as safely as possible.However,ALWAYS MAKESURE THAT THE GROUND CLIP IS CONNECTED TOTHE CHASSIS OF THE UNIT UNDER TEST AND THATTHE SWITCH ON THE PROBE IS IN THE OFF POSITIONWHEN YOU ARE NOT MAKING AN ACTUALMEASUREMENT.While the conductors inside the handle  \nMost kits returned for repair,do not function properly dueto poor solder connections.Therefore,many troubles can beeliminated if you carefully inspect all the connections tomake sure they are soldered as described in the \"Soldering\"section of the\"Kit Builders Guide.\"Reheat any doubtfulconnections and be sure all the wires are soldered at placeswhere several wires are connected.Recheck the wiring.Trace each lead in colored pencil on the Pictorial as it is  \n# SPECIFICATIONS\n\nVoltage Range .........................  0-40kVDC.  \nAccuracy ........................   ±3%of full scale.  \nSize ..........................   15”long×1-7/8\"widex1-1/2\"high.Weight .........................   8 oz.  \nThe Heath Company reserves the right to discontinueproducts and to change specifications at any time withoutincurring any obligation to incorporate new features inproducts previously sold.  \nand ground lead never have more than about a tenth of avolt across them when properly connected,these parts willbe exposed to the full oltage under test if the ground lead isnot connected to the chassis.  \nWhenever possible,contact the high voltage terminal undertest with the power turned off.Then turn the power on,slide the probe switch to the on position,take the reading,slide the probe switch to the off position,turn the poweroff,and remove the probe from the circuit under test.  \nBe sure the slide switch is in the OFF position when theProbe is not in use.  \n# OPERATION\n\nIN CASE OF DIFFICULTY  \nchecked.It is frequently helpful to have a friend check yourwork.Someone who is not familiar with the kit may noticesomething you have consistently overlooked.  \nNOTE:In an extreme case where you are unable to resolve adifficulty,refer to the \"Customer Service\"information inthe \"Kit Builders Guide.\"  \n\\#6x5/8\"HEATHKITSELF-TAPPINGNAMEPLATE  \nLARGEBLACK WIRE()Mount the meter in the handle top with the hardwaresupplied with the meter.Position the meter so that themeter scale is away from the switch.CAUTION:DoRefer to Pictorial 1 for the following steps.  \n()Mount the slide switch in t","cbCaiuZSwAQnJQhD","https://ap.wps.com/l/cbCaiuZSwAQnJQhD","pdf",2932056,"English","# INTRODUCTION\n## Copyright and References\n# PARTS LIST\n## Circuit and Components\n## Ordering and Replacement Parts\n# SPECIFICATIONS\n# OPERATION\n## In Case of Difficulty\n# STEP-BY-STEP ASSEMBLY\n## Wire Preparation and Connections","[{\"question\":\"What is the maximum DC voltage that the Heathkit IM-5210 probe meter measures?\",\"answer\":\"It measures extremely high DC voltages up to 40,000 volts, with a stated voltage range of 0–40 kV DC.\"},{\"question\":\"What safety precautions must be followed during use?\",\"answer\":\"Always ensure the ground clip is connected to the chassis and the probe switch is OFF when not making a measurement. Never measure DC voltages in excess of 40,000 volts.\"},{\"question\":\"Why are careful solder connections emphasized in this guide?\",\"answer\":\"Many returned kits fail due to poor solder connections. Carefully inspect, reheat doubtful connections, and recheck wiring as described in the “Soldering” section of the Kit Builders Guide.\"}]","40 kV Probe Meter - Model IM-5210 - Introduction and Assembly Guide | PDF",1791810231,15]