[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664027-105":59,"doc-detail-664027-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","21013-police-hq-fit-out-electrical-index-notes","21013 POLICE HQ FIT-OUT - Electrical Index - Notes","","Electrical index and general power notes for the 21013 Police HQ fit-out, outlining circuit identification, outlet and device callouts, and connection requirements across multiple plans. Specifies wall-mounted receptacles, telephone/data/AV feeds, lighting controls, disconnects, exit signs with 90-minute battery backup, fire alarm devices, and other low-voltage system interfaces. Provides installation intent for concealed branch wiring, pullbox requirements for extended conduit runs, thermostat stubbing guidance, and reuse procedures for existing light fixtures tagged for battery packs, along with compliance to relevant electrical life-safety codes.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/21013-police-hq-fit-out-electrical-index-notes/664027/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/21013-police-hq-fit-out-electrical-index-notes/664027.png","ImageObject",300,407,{"name":92,"@type":93},"Oliver","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How are electrical circuits and connections identified in these drawings?","Question",{"text":112,"@type":113},"Circuits are designated by the number shown adjacent to equipment or by the panel schedule. Wiring is only shown under special circumstances, while required conduit, wire, boxes, and fittings are included in pricing.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What wiring installation rules are specified for branch circuits?",{"text":117,"@type":113},"All branch wiring is intended to be run concealed in walls and above hung ceilings. For conduit runs exceeding (4) 90-degree bends, a pullbox must be provided.",{"name":119,"@type":110,"acceptedAnswer":120},"What battery backup and emergency requirements are stated for life-safety devices?",{"text":121,"@type":113},"Exit signs must be provided with a 90-minute battery back-up, and fixtures designated to be on emergency also require 90-minute battery back-up. Fixtures tagged 'EM' require a 90-minute integral battery pack.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664027,1793236727,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},8796095461610,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","| 21013 POLICE HQ FIT-OUT |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| \u003Cbr>GFI\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>J\u003Cbr>T\u003Cbr>AV\u003Cbr>a S\u003Cbr>SD\u003Cbr>S\u003Cbr>TS\u003Cbr>ST\u003Cbr>S 3-WAY\u003Cbr>A B C\u003Cbr>\u003Cbr>\u003Cbr>EM\u003Cbr>\u003Cbr>P D\u003Cbr>AV\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>F\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>F\u003Cbr>\u003Cbr>\u003Cbr>ABC  \u003Cbr>\u003Cbr>,(E)\u003Cbr>,(N) | WALL MOUNTED DUPLEX RECEPTACLE (20A, 120V, 3W) . NUMBER DENOTES CIRCUIT\u003Cbr>SAME AS ABOVE, BUT GFI-TYPE\u003Cbr>HOMERUN TO DESIGNATED PANEL. NUMBER NEXT TO ARROW DENOTES CIRCUITING\u003Cbr>WALL MOUNTED TELEPHONE OUTLET CONSISTING OF 4-11/16\" JUNCTION BOX, ADAPTOR RING, 1\"C STUB-UP TO ACCESSIBLE CEILING, AND DRAG WIRE\u003Cbr>JUNCTION BOX\u003Cbr>THERMOSTAT. CONTRACTOR SHALL PROVIDE A BACKBOX AND 3/4\"C STUB-UP WITH DRAG WIRE. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS\u003Cbr>WALL MOUNTED SINGLE-GANG BACKBOX WITH ADAPTOR RING, AND DRAG WIRE\u003Cbr>DECORA STYLE LIGHT SWITCH. LETTER DENOTES ZONE\u003Cbr>DIMMING SWITCH\u003Cbr>SWITCH WITH INTEGRAL PROGRAMMABLE TIMING FUNCTION FOR EXTERIOR LIGHTING.\u003Cbr>TOGGLE SWITCH FOR LOCAL DISCONNECT OF MECHANICAL EQUIPMENT\u003Cbr>TOGGLE SWITCH FOR LOCAL DISCONNECT OF MECHANICAL EQUIPMENT\u003Cbr>DISCONNECT SWITCH. 'A' = POLES, 'B' = FUSE SIZE (OR NON-FUSED), 'C' = FRAME SIZE\u003Cbr>EXIT SIGN. SHALL BE PROVIDED WITH 90 MINUTE BATTERY BACK-UP\u003Cbr>DENOTES FIXTURE TO BE ON EMERGENCY WITH 90 MINUTE BATTERY BACK-UP\u003Cbr>POWER/DATA IN-FEED FOR ELECTRIFIED FURNITURE SYSTEM (CONDUIT RUN ON CEILING OF FLOOR BELOW) . 3/4\"C FOR POWER, 2\"C FOR DATA\u003Cbr>POWER/DATA IN-FEED FOR ELECTRIFIED FURNITURE SYSTEM (OFF COLUMN/WALL) . 3/4\"C FOR POWER, 2\"C FOR DATA\u003Cbr>POWER/DATA/AV CONNECTIONS AT THE FLOOR FOR CONFERENCE TABLE\u003Cbr>POWER/DATA CONNECTIONS AT THE FLOOR FOR CONFERENCE TABLE\u003Cbr>MAGNETIC LOCK\u003Cbr>CARD READER\u003Cbr>FIRE ALARM SMOKE DETECTOR\u003Cbr>FIRE ALARM STROBE\u003Cbr>FIRE ALARM SPEAKER STROBE\u003Cbr>ABC FIRE EXTINGUISHER\u003Cbr>DENOTES EXISTING\u003Cbr>DENOTES NEW\u003Cbr>DENOTES CONDUIT TO BE RUN ON CEILING OF FLOOR BELOW (OR TRENCHED THROUGH FLOOR SLAB ON GROUND FLOOR) | ELECTRICAL INDEX |  | MECHANICAL POWER NOTES:\u003Cbr>1. THE INTENTION OF THESE ELECTRICAL DRAWINGS ARE TO SHOW THE GENERAL LAYOUT OF MECHANICAL AND/OR PLUMBING EQUIPMENT AND RESPECTIVE ELECTRICAL CONNECTIONS WITH ASSOCIATED DEVICES. THESE DRAWINGS SHALL BE UTILIZED FOR CIRCUITING PURPOSES ONLY.\u003Cbr>2. CIRCUITS ARE DESIGNATED BY NUMBER SHOWN ADJACENT TO EQUIPMENT OR BY PANEL SCHEDULE. WIRING IS ONLY SHOWN UNDER SPECIAL CIRCUMSTANCES. ALL CONDUIT, WIRE, BOXES, AND FITTINGS REQUIRED TO ENERGIZE THE EQUIPMENT SHOWN IN THE PANEL SCHEDULES SHALL BE INCLUDED IN BIG PRICING.\u003Cbr>3. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. FIELD CONDITIONS PREVAIL.\u003Cbr>4. ELECTRICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS PRIOR TO INSTALLATION OF EQUIPMENT FOR ENGINEER REVIEW AND APPROVAL. REFER TO SPECIFICATIONS FOR SHOP DRAWING LIST.\u003Cbr>5. REFER TO MECHANICAL DRAWINGS FOR THERMOSTAT LOCATIONS AND PROVIDE A 3/4\"C STUB-UP AND BACKBOX FOR EACH\u003Cbr>POWER NOTES:\u003Cbr>1. FOR EXACT LOCATION AND MOUNTING HEIGHT OF ALL POWER, TELE/DATA, AV OUTLETS, AND ELECTRIFIED FURNITURE IN-FEEDS SEE ARCHITECTURAL DRAWINGS. THIS DRAWING REFLECTS CIRCUITING INFORMATION ONLY.\u003Cbr>2. CIRCUITS ARE DESIGNATED BY NUMBER SHOWN ADJACENT TO EQUIPMENT OR BY PANEL SCHEDULE. WIRING IS ONLY SHOWN UNDER SPECIAL CIRCUMSTANCES. ALL CONDUIT, WIRE, BOXES, AND FITTINGS REQUIRED TO ENERGIZE THE EQUIPMENT SHOWN IN THE PANEL SCHEDULES SHALL BE INCLUDED IN BIG PRICING.\u003Cbr>3. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. FIELD CONDITIONS PREVAIL.\u003Cbr>4. ALL BRANCH WIRING SHALL BE RUN CONCEALED IN WALLS AND ABOVE HUNG CEILING.\u003Cbr>5. SEE DRAWING E100 FOR PANEL SCHEDULE\u003Cbr>6. WHERE CONDUIT RUNS EXCEEDS (4) 90 DEGREE BENDS, PROVIDE A PULLBOX\u003Cbr>7. ALL CIRCUIT NUMBERS REFER TO PANELS AS FOLLOWS:\u003Cbr>A. 1st FLOOR\u003Cbr>a. D\\#X = DP-1\u003Cbr>b. A\\#X = RP1-A\u003Cbr>B. 2nd FLOOR\u003Cbr>a. A\\#X = RP2-A\u003Cbr>b. B\\#X = RP2-B\u003Cbr>LIGHTING NOTES:\u003Cbr>1. CIRCUIT AND ZONE ARE DESIGNATED BY NUMBER SHOWN ADJACENT TO EACH LIGHT FIXTURE\u003Cbr>2. ALL BRANCH CIRCUITING SHALL BE RUN CONCEALED IN WALLS AND ABOVE HUNG CEILINGS.\u003Cbr>3. THE INTENT IS TO ACTIVELY RE-USE THE EXISTING LIGHT FI","cbCaio4iltNrXz7U","https://ap.wps.com/l/cbCaio4iltNrXz7U","pdf",1921461,"English","# Electrical Index\n## Electrical General Notes\n## Mechanical Power Notes\n## Power Notes\n## Lighting Notes","[{\"question\":\"How are electrical circuits and connections identified in these drawings?\",\"answer\":\"Circuits are designated by the number shown adjacent to equipment or by the panel schedule. Wiring is only shown under special circumstances, while required conduit, wire, boxes, and fittings are included in pricing.\"},{\"question\":\"What wiring installation rules are specified for branch circuits?\",\"answer\":\"All branch wiring is intended to be run concealed in walls and above hung ceilings. For conduit runs exceeding (4) 90-degree bends, a pullbox must be provided.\"},{\"question\":\"What battery backup and emergency requirements are stated for life-safety devices?\",\"answer\":\"Exit signs must be provided with a 90-minute battery back-up, and fixtures designated to be on emergency also require 90-minute battery back-up. Fixtures tagged 'EM' require a 90-minute integral battery pack.\"}]","21013 POLICE HQ FIT-OUT - Electrical Index - Notes | PDF",15]