[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662864-105":59,"doc-detail-662864-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","210100-fire-protection-system-design-2026-q2","210100 Fire Protection System Design - 2026 Q2","","Design and consultant guidelines for the University of Missouri’s fire protection systems, covering installation, design intent, and compliance with the International Fire Code and applicable NFPA standards. Specifies roles for life safety and fire control systems, AHJ permissions for changes, construction drawing requirements for firestopping, and functional maintenance expectations. Details required system components, automatic sprinkler preferences, backflow prevention, zoning and supervised devices, pump and alarm supervision integration, and design considerations for high-temperature areas, elevator-related spaces, dry/pre-action/combination systems, freezing conditions, and drainage and alarm test connections.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/210100-fire-protection-system-design-2026-q2/662864/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/210100-fire-protection-system-design-2026-q2/662864.png","ImageObject",300,407,{"name":92,"@type":93},"McGucket","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What code requirements govern installation of the fire protection systems?","Question",{"text":112,"@type":113},"All fire protection systems must be installed in accordance with the International Fire Code and applicable NFPA standards.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What systems are included in fire protection system design requirements?",{"text":117,"@type":113},"Design includes automatic sprinkler systems, alternate extinguishing systems, standpipes, fire pumps when required, fire extinguishers, supervision by the building fire alarm, and provisions for testing and inspection.",{"name":119,"@type":110,"acceptedAnswer":120},"How should automatic wet pipe sprinkler systems be configured for detection and alarm supervision?",{"text":121,"@type":113},"Flow switches must be used as the waterflow detecting device and connected to the building fire alarm system, with zoning by floor or area and each zone provided with control valves, flow switches, pressure gauges, and test drain connections.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662864,1793222830,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},1236954412713,"https://us-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","| CONSULTANT PROCEDURES & DESIGN GUIDELINES UNIVERSITY OF MISSOURI |  |\n| --- | --- |\n| 210100 Fire Protection System Design 2026 Q2\u003Cbr>GENERAL: |  |\n| 1. All fire protection systems shall be installed in accordance with the International Fire Code and applicable NFPA standards. This guideline provides additional requirements for the design and installation of Fire Protection and Fire Safety systems which will assure a functional and maintainable system over the life of the facility.\u003Cbr>2. Fire Safety systems such as smoke detectors and fire alarms are intended to increase the level of life safety.\u003Cbr>3. Fire Protection systems are intended to control fires and limit building damage.\u003Cbr>4. Where a fire sprinkler is required as part of a fire safety system, as in an assembly or residence hall occupancy, it shall be designated as a Fire Safety system.\u003Cbr>5. No fire protection system shall be removed or modified without permission of the AHJ.\u003Cbr>6. The University is responsible for the operation and maintenance of the building fire protection systems.\u003Cbr>7. Ensure construction drawings include details for all the proposed firestopping systems that could be encountered on the project based on the construction type and rating of the assemblies being penetrated. A specific Division 21 firestopping spec can be inserted, or reference related section 078400 for details.\u003Cbr>DESIGN GUIDELINES: |  |\n| 1. Fire Protection systems design includes all of the following components and systems:\u003Cbr>1.1. Automatic Sprinkler Systems\u003Cbr>1.2. Alternate Extinguishing systems\u003Cbr>1.3. Standpipes, combination and standard\u003Cbr>1.4. Fire pumps when required\u003Cbr>1.5. Fire extinguishers\u003Cbr>1.6. Supervision by the building Fire alarm\u003Cbr>1.7. Adequate provisions for testing and inspection |  |\n|  | 2. All new facilities and major renovations shall have an automatic fire sprinkler system, fire protection standpipe, fire extinguishers and fire alarm system throughout the facility, |\n\nPage 1 of 9 210100  \n\n| CONSULTANT PROCEDURES & DESIGN GUIDELINES UNIVERSITY OF MISSOURI |  |\n| --- | --- |\n| 210100 Fire Protection System Design 2026 Q2 |  |\n| | unless directed otherwise by the UM Director ofFPD. One exception is Agriculture buildings whose primary purpose is storage or animal holding.\u003Cbr>3. Building occupancies shall be determined based on International Building Code. Hazard Class occupancy shall be based on NFPA 13 and 14. See Appendix F for projects requiring FM Global installations.\u003Cbr>4. Automatic wet pipe fire sprinklers\u003Cbr>4.1. All sprinkler systems will have a double check type backflow preventer installed at the point of building entry\u003Cbr>4.2. Automatic wet pipe fire sprinkler systems are preferred.\u003Cbr>4.3. Fire department connection shall be located to provide unobstructed access as approved by the Project Manager.\u003Cbr>4.4. Automatic wet pipe sprinkler systems shall utilize flow switches as the waterflow detecting device. Flow switches shall be connected to the building fire alarm system. Buildings should be zoned by floor or by area limitations. Each zone shall have a control valve, flow switch, pressure gauge and test drain connection. All zone water flow devices, valve tamper switches and air pressure for dry pipe systems shall be supervised by the building fire alarm system.\u003Cbr>4.5. Pressure reducing valves on automatic systems are not required. Pressures are not expected to exceed pipe pressure ratings.\u003Cbr>4.6. High temperature areas\u003Cbr>4.6.1. High or intermediate temperature sprinklers heads shall be provided in all mechanical rooms, and emergency generator rooms, attics and elsewhere when elevated ambient temperatures might be expected.\u003Cbr>4.7. Elevator Shafts and Equipment Rooms\u003Cbr>4.7.1. Automatic fire sprinklers shall not be required in elevator machine rooms, elevator machinery spaces, control spaces or hoistways of traction elevators where all the conditions of 8.15.5 of NFPA 13 are met.\u003Cbr>4.8. Dry pipe, Pre-action and combination systems\u003Cbr>4","cbCairI7zFUpGjoE","https://ap.wps.com/l/cbCairI7zFUpGjoE","pdf",439483,"English","# GENERAL\n## DESIGN GUIDELINES\n# Automatic Sprinkler Systems\n## Alternate Extinguishing Systems\n## Standpipes and Fire Pumps\n## Fire Extinguishers and Alarm Supervision\n# System Requirements for New Facilities\n## Building Occupancy and Hazard Classification\n# Wet Pipe Sprinklers\n## Backflow Preventers and Flow Switches\n## Fire Department Connection\n## Zoning and Supervision\n# Dry Pipe, Pre-action and Combination Systems\n## Nitrogen Generation System Option\n# High-Temperature and Elevator-Related Spaces\n# Areas Subject to Freezing and Drainage","[{\"question\":\"What code requirements govern installation of the fire protection systems?\",\"answer\":\"All fire protection systems must be installed in accordance with the International Fire Code and applicable NFPA standards.\"},{\"question\":\"What systems are included in fire protection system design requirements?\",\"answer\":\"Design includes automatic sprinkler systems, alternate extinguishing systems, standpipes, fire pumps when required, fire extinguishers, supervision by the building fire alarm, and provisions for testing and inspection.\"},{\"question\":\"How should automatic wet pipe sprinkler systems be configured for detection and alarm supervision?\",\"answer\":\"Flow switches must be used as the waterflow detecting device and connected to the building fire alarm system, with zoning by floor or area and each zone provided with control valves, flow switches, pressure gauges, and test drain connections.\"}]","210100 Fire Protection System Design - 2026 Q2 | PDF",23]