[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-364049-105":59,"doc-detail-364049-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","2023-national-electrical-code-nec-changes-article-250-article-300","2023 National Electrical Code (NEC) Changes - Article 250 & Article 300","","2023 National Electrical Code (NEC) changes summarize key updates affecting grounding and bonding, and general wiring requirements. Article 250 clarifies what is and is not considered objectionable current, including temporary currents from ground faults, grounding electrode conductor behavior, and currents on metal raceways and equipment at the service supply side. Article 300 revises physical-protection rules for wiring beneath metal-corrugated roof decking, adds cover requirements for underground installations, expands warning-ribbon guidance for EMT, and updates how the number of conductors in a raceway is limited, now explicitly including cables to prevent insulation damage during installation.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/2023-national-electrical-code-nec-changes-article-250-article-300/364049/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/2023-national-electrical-code-nec-changes-article-250-article-300/364049.png","ImageObject",300,407,{"name":92,"@type":93},"Ezra","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",18,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What does Article 250.6 clarify about objectionable current in the 2023 NEC?","Question",{"text":113,"@type":114},"It clarifies which current types are not considered objectionable, including temporary currents from a ground fault and currents from connections not required by the article.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Why is current on grounding electrode conductors (GEC) sometimes not considered objectionable?",{"text":118,"@type":114},"The text explains that seeing 10 amperes or more can be surprising but is normal in many installations because the water pipe is electrically continuous with nearby services through the grounding electrode system and utility neutral.",{"name":120,"@type":111,"acceptedAnswer":121},"What updates appear in Article 300 for protecting wiring beneath metal-corrugated roof decking?",{"text":122,"@type":114},"The rules require wiring components under such decking to be kept at least 1 ½ inches from the lowest portion, prohibit wiring in concealed locations there, and clarify exceptions involving concrete depth and specific fitting or box types.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},364049,1790576796,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":46,"preview_page_count":19,"preview_urls":145},1099514068035,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","2023 NATIONAL ELECTRICAL CODE® (NEC®) CHANGES  \nThe National Electrical Code (NEC) is used in all 50 of the United States, as well as several countries in North, Central, and South America. It is updated every three years. As always, the National Electrical Code saw many changes in the 2023 edition, and this article discusses some of the changes that address steel conduit and tubing.  \nARTICLE 250-GROUNDING AND BONDING  \n250.6 Objectionable Current.  \nThe types of currents not considered objectionable were clarified.  \n250.6 Objectionable Current.  \n(C) Temporary Currents Not Considered Objectionable. Current from a ground fault is not considered objectionable current, nor is current from any connection required by this article.  \nFor most people, seeing 10 Amperes (or more) on a grounding electrode conductor (GEC) is surprising and seems like an immediate danger; however, it is quite normal in many installations. Section 250.50 requires an underground water pipe to be connected to the grounding electrode system if it is present. In a typical neighborhood, if the underground water pipe supplying one house is copper, every other house in the neighborhood is likely to have copper too. Because the GEC is in parallel with the utility neutral, your house’s water pipe is electrically continuous to your neighbor’s. Because the water pipe is such a good grounding electrode, it will often have nearly as much (or perhaps even more) current than your service neutral conductor and will often have current flowing even if your service is disconnected. This phenomenon has been known for well over 100 years and is not considered objectionable current.  \n2  \nAnother example of current that is not considered objectionable is the current that flows on metal raceways and equipment on the supply side of the service. The service equipment is required to be connected to the utility neutral conductor, and, ultimately, so are all other metal parts on the line side of the service. The amount of current is typically quite small, and even more importantly, the voltage on those metal parts is even lower. This installation practice has been commonplace for 150 years, and has not been shown to be hazardous, so how could it be considered objectionable?  \nARTICLE 300-GENERAL REQUIREMENTS FOR WIRING METHODS AND MATERIALS  \n300.4 Protection Against Physical Damage.  \nThe rules for protecting raceways below metal-corrugated roof decking were slightly revised.  \n300.4 Protection Against Physical Damage. Conductors, raceways, and cables must be protected against physical damage.(E) Cables, Raceways, or Boxes Under Metal-Corrugated Roof Decking. Cables, raceways, and enclosures in exposed or concealed locations under metal-corrugated sheet roof decking must be kept at least 1 ½” from the lowest portion of the decking. Wiring in concealed locations of such decking is not allowed.  \nInfo Note: This ensures that screws used for roofing material do not damage the wiring system during the initial installation or when the roof is replaced.  \nEx 1: Rigid metal conduit or intermediate metal conduit do not require this clearance if malleable iron fittings and boxes are used.  \nEx 2: This requirement does not apply if the decking is beneath 2” or more of concrete.  \nThe requirement to protect wiring beneath roof decks was clarified by adding exception number two. Although the existing informational note alluded to the fact, the Code did not clearly state that compliance was only needed for roof decks that are likely to receive roofing screws. A metal deck with 2” of concrete above it would not receive such a screw, so the exception removes any debate. The existing exception was also revised to require malleable iron fittings or boxes if the exception is to be used. This makes sense when considering aluminum fittings, but perhaps not as much sense when considering stainless steel fittings.  \n300.5 Underground Installations.  \nCover requirements for EMT were added in Column 3 ","cbCaikEoIPuZTuYy","https://ap.wps.com/l/cbCaikEoIPuZTuYy","pdf",1319400,"English","# Article 250 - Grounding and Bonding\n## 250.6 Objectionable Current\n## 250.6(C) Temporary Currents Not Considered Objectionable\n# Article 300 - General Requirements for Wiring Methods and Materials\n## 300.4 Protection Against Physical Damage\n## 300.5 Underground Installations\n## 300.17 Number of Conductors in Raceway","[{\"question\":\"What does Article 250.6 clarify about objectionable current in the 2023 NEC?\",\"answer\":\"It clarifies which current types are not considered objectionable, including temporary currents from a ground fault and currents from connections not required by the article.\"},{\"question\":\"Why is current on grounding electrode conductors (GEC) sometimes not considered objectionable?\",\"answer\":\"The text explains that seeing 10 amperes or more can be surprising but is normal in many installations because the water pipe is electrically continuous with nearby services through the grounding electrode system and utility neutral.\"},{\"question\":\"What updates appear in Article 300 for protecting wiring beneath metal-corrugated roof decking?\",\"answer\":\"The rules require wiring components under such decking to be kept at least 1 ½ inches from the lowest portion, prohibit wiring in concealed locations there, and clarify exceptions involving concrete depth and specific fitting or box types.\"}]","2023 National Electrical Code (NEC) Changes - Article 250 & Article 300 | PDF",1790155304,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/47817cc41d7402530505d4f74d5b23c0.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6aea480d15c116ed39c9e060074b38fb.webp",982,1270,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/487fe340d1ac81ca6f3cb52b0d2a86c4.webp",981,1269,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/34aca3c323006b135e763b3da2880ac8.webp",980,1268]