[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-270024-105":59,"doc-detail-270024-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","2008-series-hemodialysis-machine-spare-parts-manual-part-number-490124-rev-h","2008 Series Hemodialysis Machine - Spare Parts Manual - Part Number 490124 Rev H","","2008 Series hemodialysis spare parts manual for Fresenius Medical Care North America, covering proprietary assembly, installation, adjustment, and repair instructions for 2008K2, 2008K@Home, 2008T, and 2008T BlueStar systems. Includes general warnings and safety requirements, such as maintenance precautions with patients connected, shock-hazard and electrical outlet specifications, and the obligation to use OEM Fresenius Medical Care parts. Provides spare-part ordering steps, technical support contacts, and a structured table of contents for cabinet, caster, shunt, and dialysate line components.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/2008-series-hemodialysis-machine-spare-parts-manual-part-number-490124-rev-h/270024/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/2008-series-hemodialysis-machine-spare-parts-manual-part-number-490124-rev-h/270024.png","ImageObject",300,407,{"name":92,"@type":93},"Jiven","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-23","2026-09-15",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety precautions are required before performing maintenance on the machine?","Question",{"text":112,"@type":113},"Never perform maintenance when a patient is connected to the machine. When serviced, remove the machine from the treatment area if possible and ensure it is fully tested before returning it to clinical use.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Why must only OEM Fresenius Medical Care parts be used?",{"text":117,"@type":113},"Only original Fresenius Medical Care OEM parts should be used, since the 2008 Series Hemodialysis system is specified and tested to ANSI/AAMI/ISO guidelines. Using non-OEM parts can void warranty and may cause patient harm.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the manual recommend ordering a spare part?",{"text":121,"@type":113},"If the part number is known, call 800-227-2572 and choose Option 3 for the Spare Parts Department. If the part number is not known, first look in the manual, then call Option 4 and Option 1 for Technical Support to obtain the desired part number.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},270024,1790449674,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},1099513958607,"https://ap-avatar.wpscdn.com/avatar/100002390cf8733938c?x-image-process=image/resize,m_fixed,w_180,h_180&k=1778829742770036399","2008 SERIES HEMODIALYSIS MACHINE  \nSPARE PARTS MANUAL  \nPart Number 490124 Rev. H  \nFresenius Medical Care North America  \n920 Winter St.  \nWaltham, MA 02451  \n[http://www.fmcna.com](http://www.fmcna.com)  \n[Manufactured by:](Manufactured by:)[ ](Manufactured by:)[Fresenius USA](Fresenius USA), Inc.  \n4040 Nelson Avenue Concord, CA 94520  \n2008 Series Hemodialysis Spare Parts Manual  \n© 2008 – 2024 Fresenius Medical Care. All Rights Reserved. Fresenius Medical Care, the triangle logo, 2008, 2008K@Home, 2008T BlueStar, bibag and DIASAFE are trademarks of Fresenius Medical Care Holdings, Inc. or its affiliated companies. All other trademarks are the property of their respective owners.  \nThis document contains proprietary information ofFresenius USA, Inc. d/b/a Fresenius Medical Care North America and its affiliates (“Fresenius Medical Care”) . The contents ofthis manual may not be disclosed to third parties, copied, or duplicated in any form, in whole or in part, without the prior written permission ofFresenius USA, Inc.  \nThe 2008K2, 2008K@Home™, 2008T & 2008T BlueStar™ machines constitute the 2008® Series Hemodialysis Machines. In this manual the 2008K2 & 2008K@Home hemodialysis machines may be referred to as “2008K Series”.  \nCaution: US Federal Law restricts this device to sale by or on the order of a physician.  \nAs part of the Conditions for Coverage, it is the medical director’s responsibility that the operators of the Fresenius Medical Care 2008 Series hemodialysis machines, bibag® and Diasafe® must be trained in its operation and thoroughly familiar, being able to distinguish between normal and abnormal operation.  \nAssembly, installation, adjustment, or repair is to be performed only by persons authorized by the facility medical director or by Fresenius USA, Inc. Field Service Bulletins, and other documentation is located on the Internet at [http://www.fmcna.com](http://www.fmcna.com).  \nFor further information regarding the operation, repair, parts, or maintenance of the Fresenius Medical Care 2008 Series hemodialysis machines, please contact:  \nFresenius USA, Inc.  \n4040 Nelson Avenue (800) 227-2572  \nConcord, CA 94520  \nGeneral Warnings  \n| Warning! Never perform maintenance when a patient is connected to the machine. If possible, remove the machine from the treatment area when it is being serviced. Label the machine to ensure it is not accidentally returned to clinical use before the service work is completed. Always fully test the machine when maintenance is completed. Confirm dialysate conductivity and pH level before returning the machine to clinical use. |\n| --- |\n| Shock Hazard: Refer servicing to qualified personnel.\u003Cbr>The electrical source must be 120 volts, 60 Hz, single phase. The outlet must be a three-conductor type with a hospital-grade receptacle and a ground fault interrupter. Test the polarity and ground integrity before installation and ensure it is maintained thereafter. Failure to do so may result in electrical shock to the operator or patient |\n| Warning! Only Original Equipment Manufacturer (OEM) Fresenius Medical Care parts should be used in the repair or upgrade of the Fresenius Medical Care 2008 Series Hemodialysis System. Although, parts may look similar to parts in various vendor catalogs or brick and mortar stores the 2008 Series Hemodialysis System uses parts that have been specified and tested in accordance to ANSI/AAMI/ISO guidelines. The use of nonOEM parts will void your warranty and may cause patient harm. |\n\nHelpful Info  \nTo order a spare part:  \nIf the part number is known call: 800-227-2572 – Option 3 – Spare Parts Department to place the order.  \nIf the part number is not known, first look in this manual. If unable to find call:  \n800-227-2572 – Option 4, then Option 1 – Technical Support to obtain the desired part number.  \nTechnical documentation update notifications are available via email. To subscribe go to:  \n[http://www.fmcna.com](http://www.fmcna.com)  \nTABLE OF CONTEN","cbCaiif9U17nIOEr","https://ap.wps.com/l/cbCaiif9U17nIOEr","pdf",9245614,184,"English","# General Warnings\n# Helpful Info\n## To order a spare part\n## Technical documentation updates\n# Table of Contents\n## Statement: Minimum Testable Assemblies\n## 1.0.0 Cabinet 2008K2 & 2008K@Home\n## 2.0.0 Cabinet 2008T","[{\"question\":\"What safety precautions are required before performing maintenance on the machine?\",\"answer\":\"Never perform maintenance when a patient is connected to the machine. When serviced, remove the machine from the treatment area if possible and ensure it is fully tested before returning it to clinical use.\"},{\"question\":\"Why must only OEM Fresenius Medical Care parts be used?\",\"answer\":\"Only original Fresenius Medical Care OEM parts should be used, since the 2008 Series Hemodialysis system is specified and tested to ANSI/AAMI/ISO guidelines. Using non-OEM parts can void warranty and may cause patient harm.\"},{\"question\":\"How does the manual recommend ordering a spare part?\",\"answer\":\"If the part number is known, call 800-227-2572 and choose Option 3 for the Spare Parts Department. If the part number is not known, first look in the manual, then call Option 4 and Option 1 for Technical Support to obtain the desired part number.\"}]","2008 Series Hemodialysis Machine - Spare Parts Manual - Part Number 490124 Rev H | PDF",1789454527,464]