[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648415-105":59,"doc-detail-648415-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","1755-pickering-parkway-landscape-spa-drawing-set-general-notes-contractor-requirements","1755 Pickering Parkway Landscape SPA Drawing Set - General Notes - Contractor Requirements","","Landscape drawing set cover page and general notes for the 1755 Pickering Parkway landscape SPA in Pickering, Ontario. Specifies metric scale and drawing usage constraints marked “Not for construction,” revision history for ZBA issuances, and detailed contractor responsibilities. Notes include obtaining permits, utility staking and field verification, protection of existing utilities and works, traffic and site cleanliness during construction, submission of material samples, inspection before payment approval, and requirements for expansion joints and coordination with engineering and electrical/irrigation systems.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/1755-pickering-parkway-landscape-spa-drawing-set-general-notes-contractor-requirements/648415/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/1755-pickering-parkway-landscape-spa-drawing-set-general-notes-contractor-requirements/648415.png","ImageObject",300,407,{"name":92,"@type":93},"miraaa_2004","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-25","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What scale and measurement rules apply to these drawings?","Question",{"text":112,"@type":113},"All drawings are in metric scale. Dimensions under 1000mm are shown as whole numbers, and dimensions are given to the face of curb and face of foundation and site walls unless otherwise indicated.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What must the contractor do before starting construction?",{"text":117,"@type":113},"Obtain all required provincial or local municipal permits, arrange utility staking prior to construction, and visit the site to become familiar with existing conditions. The contractor must verify layout and report any discrepancies to the landscape architect before proceeding.",{"name":119,"@type":110,"acceptedAnswer":120},"How should the contractor handle underground utilities during excavation?",{"text":121,"@type":113},"Existing underground utilities shown are plotted from original site drawings and/or topographic survey. The contractor must use precautions, verify locations and depths prior to excavation, and be aware actual utilities may not match shown locations.",{"name":123,"@type":110,"acceptedAnswer":124},"What requirements govern concrete transitions and expansion joints?",{"text":125,"@type":113},"At edges of existing sidewalk or curb where new concrete is placed, sawcut and remove existing concrete to the nearest contraction joint for smooth transition. Install expansion joints where new concrete meets existing pavement, slabs, or footings, and place expansion joints at maximum 6-meter intervals.","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},648415,1792923914,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":147,"read_time":148},962094249165,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","January 31, 2025 2:22 PM I :\\0 1- -PROJECTS\\2020\\20 175 1755 P ICKER ING PARKWAY-P ICKER ING DESIGN CENTRE\\0 1-CAD\\0 1-CURRENT\\ PLOT\\02-SPA\\20-175 LS-100 LANDSCAPE PLAN . DWG  \n\n| \u003Cbr>\u003Cbr>ON 401 EXPRESS\u003Cbr>BROCK ROAD\u003Cbr>|  | 1755 PICKERING PARKWAY LANDSCAPE SPA DRAWING SET\u003Cbr>PICKERING, ONTARIO\u003Cbr>SHEET INDEX SHEET NUMBER SHEET TITLE LC-000 COVER PAGE LS-100 LANDSCAPE PLAN LS-101 COMPOSITE UTILITY PLAN LS-200 7TH FLOOR LANDSCAPE PLAN LD-100 LANDSCAPE DETAILS LD-101 LANDSCAPE DETAILS LD-102 LANDSCAPE DETAILS |\n| --- | --- | --- |\n| GENERAL NOTES:\u003Cbr>1. ALL DRAWINGS ARE IN METRIC SCALE. DIMENSIONS UNDER 1000mm ARE SHOWNASA WHOLE NUMBER. ALL DIMENSIONS ARE GIVEN TO FACE OF CURB AND FACE OF FOUNDATION AND SITE WALLS, UNLESS OTHERWISE INDICATED.\u003Cbr>2. CONTRACTOR SHALL OBTAIN ALL NECESSARY PROVINCIAL OR LOCAL MUNICIPAL PERMITS REQUIRED. ALL CONSTRUCTION SHALL CONFORM TO PROVINCIAL AND LOCAL MUNICIPAL STANDARDS AND CODES THAT PERTAIN TO THE SITE UNDERCONSTRUCTION.\u003Cbr>3. CONTRACTOR SHALL ARRANGE FOR UTILITY STAKING PRIOR TO START OF CONSTRUCTION. IT IS THE CONTRACTORS RESPONSIBILITY TO VISIT THE SITE PRIOR TO CONSTRUCTION TO BECOME FAMILIAR WITH EXISTING CONDITIONS. IF ANY DISCREPANCIES EXIST BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS, CONTRACTOR SHALL BRING THIS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT.\u003Cbr>4. EXISTING UNDERGROUND UTILITIES SHOWN ON THE DRAWINGS ARE PLOTTED FROM ORIGINAL SITE DRAWINGS AND/OR SITE TOPOGRAPHIC SURVEY. EVERY ATTEMPT HAS BEEN MADE TO SHOW ALL UTILITY LINES WHERE THEY EXIST. CONTRACTOR SHALL USE EVERY PRECAUTION IN EXCAVATING SINCE ACTUAL UNDERGROUND UTILITIES MAY NOT BEAS SHOWN. CONTRACTOR SHALL MAKE HIMSELF THOROUGHLY FAMILIAR WITH ALL UNDERGROUND UTILITY LOCATIONS PRIOR TO ANY EXCAVATION AND VERIFY LOCATIONS AND DEPTHS OF ALL UTILITIES.\u003Cbr>5. CONTRACTOR SHALL PROVIDE HIS OWN LAYOUT, GRADING, STAKING, AND SURVEYING REQUIRED FOR CONSTRUCTION. REFER TO EXISTING SURVEY FOR BENCHMARKSAND OTHER EXISTING INFORMATION. CONTRACTOR SHALL FIELD VERIFY LAYOUT PRIOR TO CONSTRUCTION.\u003Cbr>6. CONTRACTOR SHALL PROTECT ALL EXISTING AND NEW CONSTRUCTION FROM DAMAGE. SHOULD ANY DAMAGE OCCUR, CONTRACTOR SHALL MAKE ALL NECESSARY REPAIRS AT NO COST TO THE OWNER.\u003Cbr>7. CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS ON SITE.\u003Cbr>8. PROVIDE BARRIERS OR OTHER PROTECTION TO KEEP VEHICULAR AND PEDESTRIAN TRAFFIC AWAY FROM CONSTRUCTION AREA AND OFF NEWLY PAVED AREAS BEFORE ASPHALT OR CONCRETE HAS CURED. DO NOT LEAVE ANY HOLES OPEN OVERNIGHT.\u003Cbr>9. KEEP AREA OUTSIDE CONSTRUCTION ZONE CLEAN AND USABLE BY OTHERS AT ALL TIMES.\u003Cbr>10. CONTRACTOR SHALL SUBMIT SAMPLES OFALL PROPOSED MATERIALS FOR APPROVAL PRIOR TO PLACING ORDERS.\u003Cbr>11. ALL WORK SHALL BE INSPECTED BY LANDSCAPE ARCHITECT PRIOR TO PAYMENT APPROVAL.\u003Cbr>12. CONTRACTOR SHALL PROVIDE MARKED-UP REDLINE PLANS SHOWING AS-BUILT SITE CONDITIONS TO THE LANDSCAPE ARCHITECT, PRIOR TO OBTAINING APPROVAL OF SUBSTANTIAL COMPLETION. | 13. AT ALL EDGES OF EXISTING SIDEWALK OR CURB AGAINST WHICH NEW CONCRETE IS TO BE PLACED, SAWCUT AND REMOVE EXISTING CONCRETE BACK TO THE NEAREST CONTRACTION JOINT TO PROVIDE A SMOOTH TRANSITION TO THE NEW CONCRETE.\u003Cbr>14. INSTALL EXPANSION JOINTSATALL LOCATIONS WHERE NEW CONCRETE MEETS EXISTING CONCRETE PAVEMENT, SLABS, OR FOOTINGS.\u003Cbr>15. INSTALL EXPANSION JOINTS AT MAXIMUM 6 METER INTERVAL.\u003Cbr>16. FINAL LOCATION OF TREES SHALL BE CO-ORDINATED WITH ENGINEERING UTILITIES AND D. I. P.S. STANDARDS.\u003Cbr>17. URBAN ENTRANCES SHALL BE CONSTRUCTED PER CITY OF TORONTO STANDARD T-350 .01, FOR DETAILS REFER TO CIVIL DRAWINGS.\u003Cbr>18. CONTRACTOR SHALL LOCATE ALL UTILITIES IN THE FIELD.\u003Cbr>19. THE ASPHALT OR CONCRETE THICKNESS ON PROPOSED PRIVATE DRIVEWAY ENTRANCES SHALL BE CONSTRUCTED PER CITY STANDARD T-310 .050-8.\u003Cbr>20. REFER TO ELECTRICAL DRAWINGS FOR LIGHT POLE DETAILS.\u003Cbr>21. AN IRRIGATION SYSTEM SHALL BE PROVIDED FOR THE ENTIRE SITE.\u003Cbr>THE WATER SUPPLY SHALL BE COORDINATED WITH THE BUILDING MECHANICAL CONTRACT AND TAKEN FROM THE P-1 MECHANICAL RO","cbCaii81FfriVlCk","https://ap.wps.com/l/cbCaii81FfriVlCk","pdf",6285843,"English","# Sheet Index\n## General Notes\n## Revision History & Drawings Standards\n## Contractor Verification and Submission Requirements","[{\"question\":\"What scale and measurement rules apply to these drawings?\",\"answer\":\"All drawings are in metric scale. Dimensions under 1000mm are shown as whole numbers, and dimensions are given to the face of curb and face of foundation and site walls unless otherwise indicated.\"},{\"question\":\"What must the contractor do before starting construction?\",\"answer\":\"Obtain all required provincial or local municipal permits, arrange utility staking prior to construction, and visit the site to become familiar with existing conditions. The contractor must verify layout and report any discrepancies to the landscape architect before proceeding.\"},{\"question\":\"How should the contractor handle underground utilities during excavation?\",\"answer\":\"Existing underground utilities shown are plotted from original site drawings and/or topographic survey. The contractor must use precautions, verify locations and depths prior to excavation, and be aware actual utilities may not match shown locations.\"},{\"question\":\"What requirements govern concrete transitions and expansion joints?\",\"answer\":\"At edges of existing sidewalk or curb where new concrete is placed, sawcut and remove existing concrete to the nearest contraction joint for smooth transition. Install expansion joints where new concrete meets existing pavement, slabs, or footings, and place expansion joints at maximum 6-meter intervals.\"}]","1755 Pickering Parkway Landscape SPA Drawing Set - General Notes - Contractor Requirements | PDF",1792793410,18]