[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-366506-105":59,"doc-detail-366506-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","16-association-of-local-control-and-radiation-necrosis-with-margin-for-planned-target-volume-for-brain-metastasis-abstract-citation-id-vdaf166021-purpose-methods-results-conclusions","16 ASSOCIATION OF LOCAL CONTROL AND RADIATION NECROSIS WITH MARGIN FOR PLANNED TARGET VOLUME FOR BRAIN METASTASIS - Abstract Citation ID Vdaf166.021 - Purpose, Methods, Results, Conclusions","","PURPOSE: Compare local control (LC) and radiation necrosis (RN) rates in stereotactic radiation therapy (SRT) for brain metastasis using 0 mm versus 1 mm planned target volume (PTV) margin. METHODS: A retrospective chart review used BC Cancer databases for SRT patients between January 2022 and August 2024 with TrueBeam LINAC SRT. RESULTS: Among 179 (0 mm) and 127 (1 mm) courses, local failure and RN rates were not statistically different. CONCLUSIONS: Preliminary findings suggest a 0 mm GTV to PTV margin may yield similar LC and RN to a 1 mm margin; longer follow-up is pending.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/16-association-of-local-control-and-radiation-necrosis-with-margin-for-planned-target-volume-for-brain-metastasis-abstract-citation-id-vdaf166021-purpose-methods-results-conclusions/366506/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/16-association-of-local-control-and-radiation-necrosis-with-margin-for-planned-target-volume-for-brain-metastasis-abstract-citation-id-vdaf166021-purpose-methods-results-conclusions/366506.png","ImageObject",300,407,{"name":92,"@type":93},"Aran","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-09","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What is the study purpose regarding PTV margin in SRT for brain metastasis?","Question",{"text":112,"@type":113},"To compare local control and radiation necrosis rates when using 0 mm versus 1 mm planned target volume margins.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How were the 0 mm and 1 mm margins applied in the methods?",{"text":117,"@type":113},"From January 2022 to March 2023, a 1 mm GTV to PTV margin was used, and from April 2023 to August 2024, a 0 mm margin was used for SRT plans.",{"name":119,"@type":110,"acceptedAnswer":120},"What did the results show about local failure and radiation necrosis rates?",{"text":121,"@type":113},"Local failure and radiation necrosis rates were 23% vs 28% and 6% vs 10% for 0 mm vs 1 mm courses, with no statistically significant differences reported (p=0.28 and p=0.13).",{"name":123,"@type":110,"acceptedAnswer":124},"What is the main conclusion and what remains pending?",{"text":125,"@type":113},"A 0 mm GTV to PTV margin may produce similar local control and radiation necrosis compared with a 1 mm margin; outcomes with longer follow-up are pending.","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},366506,1790165850,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":133,"read_time":81,"preview_page_count":8,"preview_urls":147},137455076865,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Abstracts  \nABSTRACT CITATION ID: Vdaf166.021  \n16 ASSOCIATION OF LOCAL CONTROL AND RADIATION NECROSIS WITH MARGIN FOR PLANNED TARGET VOLUME FOR BRAIN METASTASIS  \nA. H. Cornell*, S. Taniguchi, A. Nichol, H. Carolan, R. Ma, J. Chan,  \nH. Choi, E. Gete, J. Oh (Vancouver, BC); ava.cornell@bccancer.bc.ca  \nPURPOSE: To compare local control (LC) and radiation necrosis (RN) rates for stereotactic radiation therapy (SRT) using 0mm vs. 1mm planned target volume (PTV) margin for brain metastasis (BM) . METHODS: A retrospective chart review was conducted using BC Cancer’s radiotherapy and Cancer Agency Information System databases for patients who underwent SRT for BM between January 2022 and August 2024. Treatments were delivered using the TrueBeam linear accelerator (LINAC) SRT technique. From January 2022 to March 2023, a 1mm gross tumour volume (GTV) to PTV margin was applied. From April 2023 to August 2024, a 0mm margin was used. SRT courses targeted one or more BMs in a single plan. Local failure (LF) was defined as persistent tumour growth, and RN as lesion enlargement resolving with steroids. RESULTS: A total of 306 SRT courses were delivered to 209 patients (median age 61 years). The median follow-up was 10 months. Among 179 (0mm) and 127 (1mm) courses, LF occurred in 41 (23%) vs. 36 (28%) (p=0.28), and RN in 10 (6%) vs. 13 (10%) (p=0.13). One-year LF-free survival was 71±5% vs. 68±5%(p=0.86), and 1-year composite RN/LF was 70±5% vs. 68±5%(p=0.96). Median overall survival was 1.4 years from SRT and 6.5 years from diagnosis; margin was not a significant factor. CONCLUSIONS: Preliminary results suggest a 0mm GTV to PTV margin for LINACSRT may result in similar LC and RN to a 1mm margin. Lesional outcomesand dosimetric parameters with longer follow-up are pending.  \nNEURO-ONCOLOGY ADVANCES • AUGUST 2025 iii5","cbCaiff4hHuqlpOB","https://ap.wps.com/l/cbCaiff4hHuqlpOB","pdf",391570,"English","# Abstract Citation ID: Vdaf166.021\n## Purpose\n## Methods\n## Results\n## Conclusions","[{\"question\":\"What is the study purpose regarding PTV margin in SRT for brain metastasis?\",\"answer\":\"To compare local control and radiation necrosis rates when using 0 mm versus 1 mm planned target volume margins.\"},{\"question\":\"How were the 0 mm and 1 mm margins applied in the methods?\",\"answer\":\"From January 2022 to March 2023, a 1 mm GTV to PTV margin was used, and from April 2023 to August 2024, a 0 mm margin was used for SRT plans.\"},{\"question\":\"What did the results show about local failure and radiation necrosis rates?\",\"answer\":\"Local failure and radiation necrosis rates were 23% vs 28% and 6% vs 10% for 0 mm vs 1 mm courses, with no statistically significant differences reported (p=0.28 and p=0.13).\"},{\"question\":\"What is the main conclusion and what remains pending?\",\"answer\":\"A 0 mm GTV to PTV margin may produce similar local control and radiation necrosis compared with a 1 mm margin; outcomes with longer follow-up are pending.\"}]","16 ASSOCIATION OF LOCAL CONTROL AND RADIATION NECROSIS WITH MARGIN FOR PLANNED TARGET VOLUME FOR BRAIN METASTASIS - Abstract Citation ID Vdaf166.021 - Purpose, Methods, Results, Conclusions | PDF",[148],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/2987f7e96a56e4273bad57a0aa785066.webp",983,1296]