[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649755-105":59,"doc-detail-649755-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","110kv-gis-building-elevations-west-dublin-substation","110kV GIS Building Elevations - West Dublin Substation","","This technical architectural drawing provides the elevations and roof plan for the 110kV Gas Insulated Switchgear (GIS) building, part of the West Dublin Substation and associated infrastructure project. The document details external building finishes, including specifications for insulated metal wall and roof cladding, as well as the inclusion of hot-dip galvanized fire escape stairs with grill treads. Created by TOBIN Consulting Engineers for planning purposes, the design includes notes regarding louvered vent requirements based on switchgear manufacturer specifications. It serves as a draft for client comment and is marked for planning status, intended to facilitate design review rather than active construction. The technical submission encompasses clear dimensional references and project-specific design parameters consistent with industrial facility development standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/110kv-gis-building-elevations-west-dublin-substation/649755/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/110kv-gis-building-elevations-west-dublin-substation/649755.png","ImageObject",300,407,{"name":92,"@type":93},"Mia  ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the intended purpose of this document?","Question",{"text":112,"@type":113},"The design is intended for planning purposes only and serves as a draft for client comment, not for construction.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What materials are specified for the exterior cladding?",{"text":117,"@type":113},"The building is designed with selected insulated metal wall and roof cladding, or similar approved materials in selected colors.",{"name":119,"@type":110,"acceptedAnswer":120},"Are there specific requirements for the switch room ventilation?",{"text":121,"@type":113},"Yes, the requirement for louvered vents in the switch room is to be confirmed based on the specific requirements provided by the switchgear manufacturer.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649755,1792806164,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},687207024478,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","| \u003Cbr>ROOF PLAN\u003Cbr>SCALE 1:125\u003Cbr>\u003Cbr>FRONT ELEVATION SCALE 1:125\u003Cbr>END ELEVATION 1 SCALE 1:125\u003Cbr>Selected insulated metal\u003Cbr>| Selected insulated metal roof cladding, or similar approved, to selected colour\u003Cbr>Selected insulated metal wall cladding, or similar approved, to selected colour\u003Cbr>Fire escape hot-dip\u003Cbr>galvanized with grill treads\u003Cbr>Selected insulated metal roof cladding, or similar approved, to selected colour\u003Cbr>Selected insulated metal wall cladding, or similar approved, to selected colour | NOTES\u003Cbr>1. DESIGN IS FOR PLANNING PURPOSES ONLY.\u003Cbr>2. DRAFT FOR CLIENT COMMENT AND IS NOT TO BE USED FOR CONSTRUCTION.\u003Cbr>3. REQUIREMENT FOR LOUVERED VENTS IN SWITCH ROOM TBC BASED ON SWITCHGEAR MANUFACTURER REQUIREMENTS.\u003Cbr>0 2.5\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>5 m\u003Cbr>A Dec. '15 PLANNING ISSUE MN DC Rev Date Description By Chkd.\u003Cbr>\u003Cbr>Client:\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>Project:\u003Cbr>WEST DUBLIN\u003Cbr>220 / 110 kV SUBSTATION & ASSOCIATED WORKS Title:\u003Cbr>110kV GIS BUILDING ELEVATIONS\u003Cbr>\u003Cbr>\u003Cbr>Scale @ A1: As Shown Prepared by: Checked: Date: M. Nolan D. Conneran October 2015 Project Director: D. Grehan Drawing Status: Planning \u003Cbr>TOBIN Consulting Engineers, Block 10-4, Blanchardstown Corporate Park, Dublin 15, Ireland.\u003Cbr>tel: +353-(0)1-8030406\u003Cbr>fax:+353-(0)1-8030409\u003Cbr>e-mail: [dublin@tobin.ie](dublin@tobin.ie)[ ](dublin@tobin.ie)[www.tobin.ie](www.tobin.ie)\u003Cbr>AECOM Infrastructure & Environment Limited, 4th Floor, Adelphi Plaza, Adelphi Centre, George's Street Upper, Dun Laoghaire.\u003Cbr>T +353 (0) 1 238 3100\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>Revision:\u003Cbr>\u003Cbr>A |\n| --- | --- | --- |","cbCair3tRpYxzvwg","https://ap.wps.com/l/cbCair3tRpYxzvwg","pdf",109066,"English","# Roof Plan and Building Elevations\n## Technical Notes and Specifications","[{\"question\":\"What is the intended purpose of this document?\",\"answer\":\"The design is intended for planning purposes only and serves as a draft for client comment, not for construction.\"},{\"question\":\"What materials are specified for the exterior cladding?\",\"answer\":\"The building is designed with selected insulated metal wall and roof cladding, or similar approved materials in selected colors.\"},{\"question\":\"Are there specific requirements for the switch room ventilation?\",\"answer\":\"Yes, the requirement for louvered vents in the switch room is to be confirmed based on the specific requirements provided by the switchgear manufacturer.\"}]","110kV GIS Building Elevations - West Dublin Substation | PDF"]