[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-562820-105":59,"doc-detail-562820-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","10-a-miniature-power-relay-dk-relays-technical-datasheet","10 A Miniature Power Relay - DK Relays - Technical Datasheet","","Technical datasheet for a compact 10 A miniature power relay (DK Relays) covering key electrical and safety performance. Features include high-capacity switching in a small package, high sensitivity with 200 mW nominal operating power, improved breakdown voltage via independent coil/contact structure, and multiple latching and sealed-construction options. It specifies dielectric withstand values (contact-to-coil and between open contacts), compliance with FCC Part 68 and relevant UL/CSA/TÜV/Japan safety requirements, and presents typical applications plus ordering, type codes, coil ratings, and contact/material characteristics.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/10-a-miniature-power-relay-dk-relays-technical-datasheet/562820/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/10-a-miniature-power-relay-dk-relays-technical-datasheet/562820.png","ImageObject",300,407,{"name":92,"@type":93},"anakgang17","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-13","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the main features of the 10 A miniature power relay?","Question",{"text":112,"@type":113},"The relay offers compact size with high-capacity switching (1 Form A, 10 A 250 V AC), high sensitivity with 200 mW nominal operating power, and high breakdown voltage enabled by independent coil and contact structure.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What dielectric breakdown voltage ratings are provided?",{"text":117,"@type":113},"It lists 4,000 Vrms for 1 min and 10,000 V surge breakdown voltage between contact and coil, and 1,000 Vrms for 1 min and 1,500 V surge breakdown voltage between open contacts.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the Cd-free contact designation work for ordering?",{"text":121,"@type":113},"Cadmium-free products are provided by adding the suffix “F” to the part number; the note states “F” is required only for 1 Form A contact type, while 2 Form A and 1 Form A 1 Form B are originally cadmium-free and do not need the suffix.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},562820,1791872283,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},962090883568,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","| |  | \u003Cbr>VDE | |\n| --- | --- | --- | --- |\n| 10 A MINIATURE POWER RELAY | DK RELAYS |  |  |\n\nFEATURES  \n1. Compact with high capacity  \nHigh capacity switching in a small package: 1 Form A, 10 A 250 V AC;  \n1 Form A 1 Form B and 2 Form A, 8 A  \n250 V AC.  \n2. High sensitivity: 200 mW nominal operating power  \n3. High breakdown voltage  \nIndependent coil and the contact  \nstructure improves breakdown voltage.  \n\n| Between contact\u003Cbr>and coil | Between open contacts |\n| --- | --- |\n| 4,000 Vrms for 1 min.\u003Cbr>10,000 V surge breakdown voltage | 1,000 Vrms for 1 min.\u003Cbr>1,500 V surge breakdown voltage |\n\nConforms with FCC Part 68  \n4. Latching types available  \n5. Sealed construction allows automatic washing.  \n6. Sockets are also available  \n7. Complies with safety standards  \nComplies with Japan Electrical Appliance and Material Safety Law requirements for operating 200 V power supply circuits, and complies with UL, CSA, and TÜV safety standards.  \nTYPICAL APPLICATIONS  \n1. Switching power supply  \n2. Power switching for various OA equipment  \n3. Control or driving relays for industrial machines (robotics, numerical control machines, etc.)  \n4. Output relays for programmable logic controllers, temperature controllers, timers and so on.  \n5. Home appliances  \nAbout Cd-free contacts  \nWe have introduced Cadmium free type products to reduce Environmental Hazardous Substances.  \n(The sufﬁx “F” should be added to the part number)  \n(Note: The Sufﬁx “F” is required only for 1 Form A contact type. The 2 Form A and 1 Form A 1 Form B contact type is originally Cadmium free, the sufﬁx “F” isnot required.)  \nPlease replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load.  \nORDERING INFORMATION  \n\n| DK\u003Cbr>Contact arrangement |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n| 1a: 1 Form A |  |  |  |  |  |  |  |  |  |  |  |\n| 2a: 2 Form A |  |  |  |  |  |  |  |  |  |  |  |\n| 1a1b: 1 Form A 1 Form B |  |  |  |  |  |  |  |  |  |  |  |\n| Operating function |  |  |  |  |  |  |  |  |  |  |  |\n| Nil: Single side stable |  |  |  |  |  |  |  |  |  |  |  |\n| L2: 2 coil latching |  |  |  |  |  |  |  |  |  |  |  |\n| Coil voltage (DC) |  |  |  |  |  |  |  |  |  |  |  |\n| 3, 5, 6, 9, 12, 24V |  |  |  |  |  |  |  |  |  |  |  |\n| Contact material\u003Cbr>F: 1 Form A (AgSnO2 type)\u003Cbr>Nil: 2 Form A, 1 FormA 1 Form B (Au-flashed AgNi type) |  |  |  |  |  |  |  |  |  |  |  |\n\nNotes: 1 . UL/CSA, TÜV approved type is standard.  \n2. VDE approved type is available.  \nDK  \nTYPES  \n\n| Contact\u003Cbr>arrangement | Nominal coil\u003Cbr>voltage | Single side stable | 2 coil latching |\n| --- | --- | --- | --- |\n|  |  | Part No. | Part No. |\n| 1 Form A | 3V DC | DK1a-3V-F | DK1a-L2-3V-F |\n|  | 5V DC | DK1a-5V-F | DK1a-L2-5V-F |\n|  | 6V DC | DK1a-6V-F | DK1a-L2-6V-F |\n|  | 9V DC | DK1a-9V-F | DK1a-L2-9V-F |\n|  | 12V DC | DK1a-12V-F | DK1a-L2-12V-F |\n|  | 24V DC | DK1a-24V-F | DK1a-L2-24V-F |\n| 1 Form A\u003Cbr>1 Form B | 3V DC | DK1a1b-3V | DK1a1b-L2-3V |\n|  | 5V DC | DK1a1b-5V | DK1a1b-L2-5V |\n|  | 6V DC | DK1a1b-6V | DK1a1b-L2-6V |\n|  | 9V DC | DK1a1b-9V | DK1a1b-L2-9V |\n|  | 12V DC | DK1a1b-12V | DK1a1b-L2-12V |\n|  | 24V DC | DK1a1b-24V | DK1a1b-L2-24V |\n| 2 Form A | 3V DC | DK2a-3V | DK2a-L2-3V |\n|  | 5V DC | DK2a-5V | DK2a-L2-5V |\n|  | 6V DC | DK2a-6V | DK2a-L2-6V |\n|  | 9V DC | DK2a-9V | DK2a-L2-9V |\n|  | 12V DC | DK2a-12V | DK2a-L2-12V |\n|  | 24V DC | DK2a-24V | DK2a-L2-24V |\n\nStandard packing: Tube: 50 pcs.; Case: 500 pcs.  \nRATING 1. Coil data  \n1) Single side stable  \n\n| Nominal coil\u003Cbr>voltage | Pick-up voltage\u003Cbr>(at 20°C 68°F) | Drop-out voltage\u003Cbr>(at 20°C 68°F) | Nominal operating current\u003Cbr>[±10%](at 20°C 68°F) | Coil resistance\u003Cbr>[±10%](at 20°C 68°F) | Nominal operating\u003Cbr>power | Max. allowable voltage\u003Cbr>(at ","cbCaicrGkgmtvpzB","https://ap.wps.com/l/cbCaicrGkgmtvpzB","pdf",136277,"English","# Features\n# Typical Applications\n# Cd-free Contacts\n# Ordering Information\n## DK Types\n# Rating 1: Coil Data\n## Single Side Stable\n## 2 Coil Latching\n# DK 2: Specifications","[{\"question\":\"What are the main features of the 10 A miniature power relay?\",\"answer\":\"The relay offers compact size with high-capacity switching (1 Form A, 10 A 250 V AC), high sensitivity with 200 mW nominal operating power, and high breakdown voltage enabled by independent coil and contact structure.\"},{\"question\":\"What dielectric breakdown voltage ratings are provided?\",\"answer\":\"It lists 4,000 Vrms for 1 min and 10,000 V surge breakdown voltage between contact and coil, and 1,000 Vrms for 1 min and 1,500 V surge breakdown voltage between open contacts.\"},{\"question\":\"How does the Cd-free contact designation work for ordering?\",\"answer\":\"Cadmium-free products are provided by adding the suffix “F” to the part number; the note states “F” is required only for 1 Form A contact type, while 2 Form A and 1 Form A 1 Form B are originally cadmium-free and do not need the suffix.\"}]","10 A Miniature Power Relay - DK Relays - Technical Datasheet | PDF",1791809797,18]