[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-398644-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-398644-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","0516v-resistance-to-light-astm-f1515-test-report","0516V Resistance to Light - (ASTM F1515) - Test Report","","Test Report for resilient flooring product “0516V Strand” (Style 0516V, lot #1505121, thickness 0.098\", size 457.2mm x 914.4mm) evaluated light stability and color change after accelerated lighfastness exposure. Three specimens were measured with a Hunter Colorquest instrument (∆E recorded), then exposed in an Atlas Ci35 fadeometer under specified lamp cooling, continuous light cycle, temperature and relative humidity, with defined outer/inner filters and irradiance. After 300 hours, specimens were re-read for ∆E; average ∆E was 1.41, meeting the requirement (∆ ≤ 8.0) and passing.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/0516v-resistance-to-light-astm-f1515-test-report/398644/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/0516v-resistance-to-light-astm-f1515-test-report/398644.png","ImageObject",300,407,{"name":42,"@type":43},"Finn","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-28","2026-09-27",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",11,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What standard and purpose were used to evaluate the flooring?","Question",{"text":63,"@type":64},"The test used ASTM F1515 to measure light stability of resilient flooring by color change (∆E).","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were the specimens exposed during the accelerated lighfastness test?",{"text":68,"@type":64},"Three specimens were placed in an Atlas Ci35 fadeometer with continuous light and specified temperature (145°F) and relative humidity (30%), using Soda Lime and Borosilicate filters and irradiance of 1.10 w/cm² for 300 hours.",{"name":70,"@type":61,"acceptedAnswer":71},"What was the test result for color change after exposure?",{"text":72,"@type":64},"The average ∆E after exposure was 1.41, which satisfied the requirement of ∆ ≤ 8.0, so the result was a pass.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},398644,1790696137,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":30,"preview_page_count":22,"preview_urls":145},34359740700684,"https://ap-avatar.wpscdn.com/avatar/1f400023980c374ae676?_k=1777273430885731487","TSi  \nTESTING SERVICES, INC.  \n817 SHOWALTER AVE., PO BOX 2041  \nDALTON, GA 30722‐2041  \nPHONE: (706)226‐1400 FAX: (706)226‐6118  \nTEST REPORT  \nCLIENT:  \n\n| Company: | ShawContract | Report Number: | 65639J-02 |\n| --- | --- | --- | --- |\n| Address: | PO Drawer 2128 | Lab Test Number: | 2759-5506 |\n|  | Dalton, GA 30722 | Test Date: | 11/20/2015 |\n|  |  | Report Date: | 11/23/2015 |\n|  |  | Page: | 1 of 1 |\n| Requested By: | Stuart Bartenfield |  |  |\n\nTEST MATERIAL:  \n\n| Material Type: | Resilient Flooring |  |  |  |  |  | Date Received: |  |  | 10/20/2015 |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Material Condition: | EXCELLENT: | XXX | GOOD: |  |  | POOR: |  |  | REJECTED: |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n| Style: | 0516V Strand | Lot \\#: |  | 1505121 |  |  | Size: | 457.2mmX 914.4mm (18” X 36”) |  |  |  |\n| Thickness: | 0.098” | GSA SIN \\# |  | 31-401 Resilient (Hard Surface) Tile |  |  | Test \\#: | 101915-2B |  |  |  |\n\nTESTING METHODS REQUESTED:  \n\n| Testing Services Inc. was instructed by the client to test for the following… |  |  |  |\n| --- | --- | --- | --- |\n| Standard: | ASTM F1515 | Test Method: | Standard Test Method for Measuring Light Stability of Resilient Flooring by Color Change |\n\nSAMPLING PLAN:  \n\n| Sampling Date: | 10/20/2015 |\n| --- | --- |\n| • Specimen sampling is performed in the sampling department at TSI.\u003Cbr>• The sampling size of specimens is determined by the test method requirements.\u003Cbr>• In the eventa specific sampling size is not called for, a determination will be made based on previous testing experience, and approved for use by an authorized manager.\u003Cbr>• All samples are subjected to the outside environmental conditions of temperature and relative humidly.\u003Cbr>• Sample requiring pre-determined exposure to specified environmental conditions based on a specific test method, take place in the departments in which they are tested |  |\n\nDEVIATION FROM TEST METHOD:  \n\n| State reason for any Deviation from, Additions to, or Exclusions From Test Method. |\n| --- |\n| None |\n\nTEST OVERVIEW: This test procedure determines the color change of the resilient flooring after exposure to accelerated lighfastness.  \nThree specimens of the resilient flooring were read by Hunter Colorquest instrument and its color matrix,∆E, recorded. The specimens were then placed into an Atlas Ci35 fadeometer with the following  \nsettings: Lamp Cooling: Water  \nLight Cycle: Continuous  \nTemp: 145°F  \nRH: 30%  \nFilter (Outer): Soda Lime  \nFilter (Inner): Borosilicate  \nIrradiance: 1.10 w/cm²  \nThe specimens were exposed for 300 hours, removed, and re-read by the colorquest for ∆E color change.  \nTEST DATA:  \n\n| Average ∆E Reading After Exposure | Requirement | Comment |\n| --- | --- | --- |\n| 1.41 | ∆ ≤ 8.0 | Passes |\n\nApproval:  \nErle Miles, Jr. VP, Testing Services Inc  \nTSi Accreditation: Our laboratory is accredited by the US Dept of Commerce, National Institute of Standards and Technology: ISO/IEC 17025:2005. Our code \\# is:  \nNVLAP 100108-0.  \n\n| Form: | Rev: | Revision Date: | Page 1 of 1 |\n| --- | --- | --- | --- |\n| Release Date: | Control Type: Electronic – Expires 24 hours after this date: Jan. 24, 19\u003Cbr>Printed copies are uncontrolled |  |  |\n\nOUR LETTERS AND REPORTS APPLY ONLY TO THE SAMPLE TESTED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS. THESE LETTERS AND REPORTS ARE FOR THE USE ONLY OF THE CLIENT TO WHOM THEY ARE ADDRESSED AND THEIR COMMUNICATION TO ANY OTHERS ORTHE USE OF THE NAME TESTING SERVICES, INC. MUST RECEIVE OUR PRIOR WRITTEN APPROVAL. THE REPORTS AND LETTERS, AND OUR NAME, OUR SEALS, OR OUR INSIGNIA ARE NOT UNDER ANY CIRCUMSTANCES TO BE USED IN ADVERTISING TO THE GENERAL PUBLIC.","cbCaiu8v2zMiDyJf","https://ap.wps.com/l/cbCaiu8v2zMiDyJf","pdf",242411,"English","# Test Information\n## Client and Report Details\n## Test Material Identification\n## Testing Method (ASTM F1515)\n# Testing Procedure\n## Sampling Plan\n## Deviation Statement\n## Test Overview and Fadeometer Settings\n# Results and Approval\n## ΔE Data and Pass/Fail Criteria\n## Sign-off and Accreditation","[{\"question\":\"What standard and purpose were used to evaluate the flooring?\",\"answer\":\"The test used ASTM F1515 to measure light stability of resilient flooring by color change (∆E).\"},{\"question\":\"How were the specimens exposed during the accelerated lighfastness test?\",\"answer\":\"Three specimens were placed in an Atlas Ci35 fadeometer with continuous light and specified temperature (145°F) and relative humidity (30%), using Soda Lime and Borosilicate filters and irradiance of 1.10 w/cm² for 300 hours.\"},{\"question\":\"What was the test result for color change after exposure?\",\"answer\":\"The average ∆E after exposure was 1.41, which satisfied the requirement of ∆ ≤ 8.0, so the result was a pass.\"}]","0516V Resistance to Light - (ASTM F1515) - Test Report | PDF",1790486629,[146],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/a0ea037682cfc40c624467101e005acb.webp",983,1272]